50
In standard configuration the printer prints the temperature
according to parameter list:
tPrA
= intervall of print ( it is possible to decide interval of prints in
minutes * standard is 5 minutes)
tPrC
= intervall of print during mantenance, if value is 0 does not print
anything.
PALL
=enable the print of probes temperature:
Y= print all probes temperature
N=print temperature of cell and food probe
E485
= external connection
- Prn=external printer
- PC= personal computer
Special functions
Summary of Contents for BLAST CHILLER LW
Page 1: ...BLAST CHILLER LW 595R18700 ...
Page 3: ...Electronic control Cruise version CRUISE version ...
Page 53: ...Blast Chiller or Freezer First point installation Code check Safety device Description ...
Page 92: ...Remote cooling unit information What you must know to respect a correct installation ...
Page 102: ... T1 T2 AP AP AT AT Electrical connection Find the terminals inside the electrical box ...