Parameter
ID
Parameter
Description
Table
Min
Max Default
107
CFon
Sets evaporator fan ON time when compressor is OFF. Valid
only for Conserve cycles
0 18000
120
108
CFof
Sets evaporator fan OFF time when compressor is OFF. Valid
only for Conserve cycles
0 18000
900
109
snLC
Minimum value for cavity set point temperature in cooling cycles
-50
125
-41
110
snHC
Maximum value for cavity set point temperature in cooling cy-
cles
-50
125
10
111
snLH
Minimun value for cavity set point temperature in heating cycles
-50
125
-18
112
snHH
Maximum value for cavity set point temperature in heating cy-
cles
-50
125
40
113
SCA
Cavity set point for soft chilling cycle
-50
125
0
114
SCH
Cavity set point for hard chilling cycle
-50
125
-20
115
HSP
Maximum value for cavity set point temperature in positive con-
serve
-50
125
10
116
MSP
Minimum value for cavity set point temperature in positive con-
serve
and Maximum value for cavity set point temperature in negative
conserve
-50
125
0
117
LSP
Minimum value for cavity set point temperature in negative con-
serve
-50
125
-25
121
CAL
Cavity probe calibration
-50
50
0
123
dIFP
Positive differential for compressor re-start. Reached the set-
point, the compressor will start again at 'SDIFP'.
0
50
1
124
dIFN
Negative differential for compressor stop. Reached the setpoint,
the compressor will start again at 'Setpoint-DIFN'.
0
50
1
125
dFHC
Hysteresis to switch from heating to cooling when both the mo-
dalities are enabled
0
50
2
126
dFCH
Hysteresis to switch from cooling to heating when both the mo-
dalities are enabled
0
50
5
127
nFP
Defines the total probes in the food probe for the appliance
0
6
3
128
EFP
Defines the number of separated food probes in the applicance
0: no probe available
1: only one food probe that can be 1,3 or 6 probes (according
to PAR_NUM_FOOD_PRB )
2: two food probes that can be only with 3 probes each
(PAR_NUM_FOOD_PRB=6)
3: two food probes that can be only with 1 probe each
(PAR_NUM_FOOD_PRB=3)
0
3
1
130
dsr
Delay time before food probe or time cycle selections after
evaporator fans start
0
240
30