DOC
NUMBER
595R495
110
SERVICE MANUAL Blast Chiller Freezer 100 - 200
6.3.8 Evaporator probe
Steps for replacing the Evaporator probe:
30. Open the electrical box following the procedure described in the paragraph [
Front panel
] and disconnect
the cable.
31. With the adhesive tape, tie the new probe to the cable end (Step 2).
32. Follow the procedure in the paragraph [
Opening the fan casing
].
33. Cut any cable ties that block the probe cable (Step 3) and pull, accompanying the new cable.
6.3.9 Food probe
Steps for replacing the Food probe:
34. Open the electrical box following the procedure described in the paragraph [
Front panel
] and disconnect the cable.
35. Tie a wire (called messenger) to the cable end with adhesive tape, so that it can be used as a guide for
the cable of the new probe (Figure 1 Step 2).
36. Pull the messenger cable paying attention to the length of the probe cable that remains inside the ma-
chine, the ideal measurement is shown in figure 2.