DOC
NUMBER
595R495
127
SERVICE MANUAL Blast Chiller Freezer 100 - 200
6.4.17 Compressor
Steps for replacing the Compressor:
126.
Follow the procedure in paragraph [
Upper Panel
] to reach the compressor.
127.
Close the low pressure supply by screwing clockwise the valve,
then wait for 10 minutes
(Fig.
1).
128.
Close the high pressure supply by screwing clockwise the valve (Fig. 2).
129.
Connect the vacuum pump and create vacuum in the compressor.
130.
Shut down the power supply to the appliance.
131.
Disconnect the wiring to the compressor.
132.
Unscrew the two screws from each valve (low and high pressure) to release the compressor from
the circuit (Fig. 1-2).
133.
Remove the cover of the compressor electrical box and disconnect the power cables (Fig. 3).
134.
Unscrew the four nuts at the basement of the compressor to release it from the chassis (Fig. 4).