DOC
NUMBER
595R495
112
SERVICE MANUAL Blast Chiller Freezer 100 - 200
6.3.11 Door seal
39. Remove the screws located under the gasket as shown in the detail in the figure.
40. When refitting the new gasket, make sure that the gasket locking plates are positioned correctly.
6.3.12 Handle
41. Handle: remove the 4 screw caps with a small flat-head screwdriver.
42. Door latch:
43. Handle lock:
44. Door closing pin: