6.3.6 Cell probe
Steps for replacing the Cell probe:
22. Open the electrical box following the procedure described in the paragraph [
Front panel
] and disconnect the cable.
23. With the adhesive tape, tie the new probe to the cable end (Step 2).
24. Follow the procedure in the paragraph [
Opening the fan casing
].
25. Cut the clamps that secure the probe cable (Step 3) and pull, accompanying the new cable.
6.3.7 Evaporator probe (out)
Steps for replacing the Evaporator probe:
26. Open the electrical box following the procedure described in the paragraph [
Front panel
] and disconnect the cable.
27. With the adhesive tape, tie the new probe to the cable end (Step 2).
28. Follow the procedure in the paragraph [
Opening the fan casing
].
29. Cut the clamps that secure the probe cable (Step 3) and pull, accompanying the new cable.