6.4.24 Condenser
Steps for replacing the Condenser:
ATTENTION!
Before replacing the condenser, make sure that the suction valve and the exhaust gas valve are closed and follow
the important procedures shown on page 103.
Make also sure you have closed the water circuit.
162.
Remove the front panel as explained in the paragraph [
Upper Panel
].
163.
Desolder the two condenser connection pipes, as shown in figure 1.
164.
Disconnect the water inlet and outlet pipes, as shown in figure 2.
165.
Unscrew the two screws of the condenser holding bracket.