ELECTRO FREEZE Soft Serve Model 99T-RMT
184621
25
Important:
Always inspect the transfer hose
during assembly for wear. Do not use
tools or sharp objects to remove hose.
7
Assembly
(continued)
—continued
Important:
Use original Electro Freeze transfer
hose only. Your freezer will not
operate properly with any other type
of hose. Never twist the transfer
hose when assembling or installing.
Important:
Replace transfer hose every 30 days.
13. Assemble the MTS hose
assembly as shown in figures 7-5 and
7-6. The transfer hose has a red locat-
ing line. Hold the mix/air inlet port with
the transfer hose mix port on your right
and the barbed air port facing away
from you. With the locating line up, slide
the mix tranfer hose onto the port. Then
slide a clamp over the hose to secure it
to the port. Finger tighten only! The
thumbscrew must lie parallel to the mix/
air inlet port.
14. Slide another clamp over the
mix transfer hose and connect to the
barbed end of the braided hose. Tighten
the clamp. Finger tighten only! The
thumb screw must lay horizontal as
shown in figure 7-6.
15. Slide the air tube over the air
inlet port and insert air meter in the
opposite end of the air tube.
16. Install o-ring on mix inlet tube
assembly and lubricate. Place the tube
assembly end into the port assembly
and swing retainer clip over to lock tube
assembly in place.
17. Install mix tube boot with flat
side first, over the tube assembly.
18. Insert the duckbill valve into the
bottom of the pickup tube. Push until
the two ribs are completely inserted.
Figure 7-6 Assembling MTS
Figure 7-5 MTS Hose Assembly