ELECTRO FREEZE Soft Serve Model 99T-RMT
184621
21
6.3 Cleaning Instructions
(continued)
b. The head plunger openings,
center plunger ports, O-ring grooves,
dispense nozzle mounting rings, and mix
ports, as shown in figure 6-6.
c. The shaft cup seals, washers,
and O-rings, plunger O-ring grooves and
nozzles, as shown in figure 6-7.
d. The air bleed plug O-ring
grooves.
e. The beater shaft and the
scraper blade pin holes as shown in
figure 6-8.
Important:
Do not leave parts in sanitizer for
more than 15 minutes.
3. After all parts are washed, rinse
and then place them in the sanitizer
solution. Brush the inside of all mix
transfer hoses with sanitizer. For proper
sanitizing, the parts must remain fully
immersed in the sanitizer for 5 minutes.
Allow parts to air-dry after sanitizing.
4. Using a warm dish detergent
solution thoroughly brush; the mix feed
tubes from the refrigerated cabinet to the
cylinders as shown in figure 6-9, the
inside of the cylinders including the back
wall, and the inside of the drain tube, as
shown in figure 6-10. Then rinse with
clear water and brush with sanitizing
solution.
5. Remove the drip tray and insert.
Wash in a warm dish detergent solution,
rinse with clear water, and brush with
sanitizing solution
6. Wash the outside of the freezer
and inside of the cabinet with a warm
dish detergent solution. Rinse with clear
water.
Figure 6-8
Clean beater shaft pin holes.
Replace worn brushes. Use
only Electro Freeze original
or authorized replacement
parts. See Accessories parts
list in Part II of this Manual to
order new brushes.
Figure 6-10
Brush inside of drain tube
Figure 6-7
Clean O-ring grooves, seal
and nozzle with brush.
Figure 6-9
Brush inside of cylinder mix
feed tubes.