ELECTRO FREEZE Soft Serve Model 99T-RMT
28
184621
8
Start-up Instructions
CAUTION
Mix Transfer System will be pressurized during operation. Make sure
all components and fasteners are secure before start-up.
The washing and sanitizing instructions
explained in this manual are important
procedures to remove bacteria and
maintain a clean, sanitary freezer. The
soft serve freezer must be disassembled
and washed according to the instructions
in the manual. Always sanitize before
start-up to ensure the best possible
cleanliness.
CAUTION
To prevent bacteria growth,
use only approved
sanitizers to sanitize the
machine. Sanitizing must
be done just prior to
starting the machine.
Failure to do so could
create a health hazard.
Important:
Do not use unapproved sanitizers or
laundry bleach. These materials may
contain high concentrations of chlo-
rine and will chemically attack freezer
components.
Note:
It is your responsibility to be
aware of, and conform to, the require-
ments for meeting all local, state, and
federal laws concerning the frequency of
cleaning and sanitizing the freezer.
1. Wash and sanitize your hands
and forearms.
8.1
Sanitizing Instructions
2. Prepare 2 gallons (7.5 liters) of
sanitizing solution in each mix container.
Sanitizing solution must be mixed
according to manufacturer ’s instructions
to yield 100 PPM available chlorine
solution (example: Stera-Sheen Green
Label). Use warm water (100 to 110°F
or 37 to 43°C) to wash, rinse, and
sanitize.
3. Clean the mix tank interior walls,
the underside of the tank covers, and
low mix probes (see figure 8-1 probe
assembly) with sanitizer solution and
the appropriate brush provided.
4. Place the mix tanks with sani-
tizer in the refrigerated cabinet.
Important:
Never let the sanitizer remain in the
freezer for longer than 15 minutes.
5. Insert the tube assemblies into
the sanitizer solution and sanitize the
outside portion. If plastic mix bag sys-
tems are used, be sure all adaptors and
items that will come into contact with
mix are sanitized.
6. Place an empty container under
the dispensing head.
7. Open the air bleed plugs by
pulling up until the plugs touch the
bottom of the switch box.
— continued