ELECTRO FREEZE Soft Serve Model 99T-RMT
12 Troubleshooting Tables
(continued)
PROBLEM
PROBABLE CAUSE
REMEDY
1. Pr
oduct too cold.
1.
Check product temperature. Should be
18°F (-7.8°C). See Dispensed Product
Too Cold.
2.
Low overrun.
2.
Check air meter. If plugged, clean. See
MTS Troubleshooting-No Air (Overrun).
3.
MTS problem.
3.
See MTS Troubleshooting Charts
Product
dispenses
slowly out of
dispensing
head.
4.
Dispensed speed set to slow.
4.
Contact your Electro Freeze distributor
for service.
1. Low overrun.
1. Check overrun, if low see MTS
Troubleshooting Chart.
2. Cylinder thermostat erratic or set too
cold.
2. Contact your Electro Freeze Distributor
for service.
3. Plunger switch electrically or
mechanically stuck closed.
(Unit runs all the time.)
3. Contact your Electro Freeze Distributor
for service.
4. Component failure.
4. Contact your Electro Freeze Distributor
for service.
5. Low suction pressure, refrigeration
system.
5. Contact your Electro Freeze Distributor
for service.
Dispensed
product too
hard.
6. Dispensed speed set to slow.
6. Contact your Electro Freeze Distributor
for service.
1.
Blades installed upside down.
1. Install properly – flat side to cylinder
wall.
2.
Dirty or blocked condenser, restricted air
flow.
2. Unblock condenser or have cleaned by
your Electro Freeze Distributor.
3.
Component failure.
3. Contact your Electro Freeze Distributor.
Dispensed
product too
soft. (Product
temperature
above 19°F
[-7.2°C] )
4.
Leak in refrigeration system resulting in
little or no refrigeration.
4. Contact your Electro Freeze Distributor.