ELECTRO FREEZE Soft Serve Model 99T-RMT
18
184621
Figure 6-2 Head Assembly
6.2 Disassembly Instructions
CAUTION
To avoid electrical shock or
contact with moving parts,
make sure all switches are in
the “OFF” position and that
the main power supply is
disconnected. Some
freezers have more than one
disconnect switch.
CAUTION
Make sure freezer is
depressurized before
proceeding.
CAUTION
To prevent bacteria growth,
remove ALL O-rings when
disassembling for cleaning.
Failure to do so could
create a health hazard.
1. If there is product in the freezer,
refer to Section 9, Closing Procedures,
9.2 Draining Product.
2. Remove the plunger rods (7,
figure 6-2) by lifting up and swinging the
bottom out and down. Remove hand
knobs (11) and pull the dispensing head
(1) straight out.
3. Remove the bushings and beater
shafts from the cylinders.
4. Remove scraper blades and
shaft seals from the beater shafts.
5. Remove the drip tray (see Re-
placement Parts Manual - Panel Assem-
bly) and drip tray insert from the front of
the freezer.
6. Remove the air bleed plugs (6,
figure 6-2) and remove the two O-rings
(5) on each plug. (See figure 6-2)