5-78
PERFORMANCE DATA & PRESSURE CURVES
Revision Y05-03
Service Manual - WNG
5.58.2
Heating Mode at 7.5m Tubing Connection.
230V : Indoor Fan at High Speed.
ENTERING AIR DB ID COIL ( °C)
15
20
25
ENTERING AIR WB
OD COIL (°C)
TH
PI
TH
PI
TH
PI
-10
1.49 0.74 1.43 0.78 1.37 0.82
-7
1.60 0.75 1.54 0.80 1.49 0.84
-2
1.70 0.76 1.64 0.81 1.58 0.86
2
2.07 0.80 1.98 0.85 1.90 0.90
6
2.91 0.86
2.83 0.92
2.73 0.98
10
3.17 0.91 3.08 0.97 3.00 1.04
15
3.42 0.95 3.34 1.02 3.25 1.09
20
3.61 0.98 3.52 1.06 3.42 1.14
*
the above chart includes the weighted deicing infleuence.
LEGEND
TH –
Total Heating Capacity, kW
PI
– Power Input, kW
WB –
Wet Bulb Temp., (
o
C)
DB –
Dry Bulb Temp., (
o
C)
ID
–
Indoor
OU –
Outdoor
5.59
Capacity Correction Factor Due to Tubing Length
5.59.1 Cooling
TOTAL TUBING LENGTH (One Way)
3m
7.5m
10m
15m
20m
25m
30m
40m
50m
1.03
1
0.971
0.949
---
---
---
---
---
*
Minimum recommended tubing length between indoor and outdoor units is 3m.
5.59.2 Heating
TOTAL TUBING LENGTH (One Way)
3m
7.5m
10m
15m
20m
25m
30m
40m
50m
1.04
1
0.973
0.961
---
---
---
---
---
*
Minimum recommended tubing length between indoor and outdoor units is 3m.
Summary of Contents for GC 22 ST
Page 47: ...4 5 OUTLINE DIMENSIONS Revision Y05 03 Service Manual WNG 4 9 OU8 33 RC ST 4 10 OU10 36 RC ST...
Page 71: ...5 24 PERFORMANCE DATA PRESSURE CURVES Revision Y05 03 Service Manual WNG 5 18 2 Heating...
Page 91: ...5 44 PERFORMANCE DATA PRESSURE CURVES Revision Y05 03 Service Manual WNG 5 33 2 Heating...
Page 95: ...5 48 PERFORMANCE DATA PRESSURE CURVES Revision Y05 03 Service Manual WNG 5 36 2 Heating...