5-50
PERFORMANCE DATA & PRESSURE CURVES
Revision Y05-03
Service Manual - WNG
5.372.2
Heating Mode at 7.5m Tubing Connection.
230V : Indoor Fan at High Speed.
ENTERING AIR DB ID COIL ( °C)
15
20
25
ENTERNING AIR
WB OU COIL (ºC)
TH
PI
TH
PI
TH
PI
-10
1.17 0.55 1.13 0.59 1.08 0.62
-7
1.26 0.57 1.22 0.60 1.17 0.63
-2
1.34 0.57 1.29 0.61 1.25 0.64
2
1.63 0.60 1.56 0.64 1.49 0.68
6
2.30 0.65
2.23 0.69
2.15 0.73
10
2.50 0.68 2.43 0.73 2.36 0.78
15
2.70 0.71 2.63 0.77 2.56 0.81
20
2.84 0.73 2.78 0.79 2.70 0.86
*
the above chart includes the weighted deicing infleuence.
LEGEND
TH –
Total Heating Capacity, kW
PI
– Power Input, kW
WB –
Wet Bulb Temp., (
o
C)
DB –
Dry Bulb Temp., (
o
C)
ID
–
Indoor
OU –
Outdoor
5.38
Capacity Correction Factor Due to Tubing Length
5.38.1 Cooling
TOTAL TUBING LENGTH (One Way)
3m
7.5m
10m
15m
20m
25m
30m
40m
50m
1.03
1
0.971
0.949
---
---
---
---
---
*
Minimum recommended tubing length between indoor and outdoor units is 3m.
5.38.2 Heating
TOTAL TUBING LENGTH (One Way)
3m
7.5m
10m
15m
20m
25m
30m
40m
50m
1.04
1
0.955
0.861
---
---
---
---
---
*
Minimum recommended tubing length between indoor and outdoor units is 3m.
Summary of Contents for GC 22 ST
Page 47: ...4 5 OUTLINE DIMENSIONS Revision Y05 03 Service Manual WNG 4 9 OU8 33 RC ST 4 10 OU10 36 RC ST...
Page 71: ...5 24 PERFORMANCE DATA PRESSURE CURVES Revision Y05 03 Service Manual WNG 5 18 2 Heating...
Page 91: ...5 44 PERFORMANCE DATA PRESSURE CURVES Revision Y05 03 Service Manual WNG 5 33 2 Heating...
Page 95: ...5 48 PERFORMANCE DATA PRESSURE CURVES Revision Y05 03 Service Manual WNG 5 36 2 Heating...