5-30
PERFORMANCE DATA & PRESSURE CURVES
Revision Y05-03
Service Manual - WNG
5.22.2
Heating Mode at 7.5m Tubing Connection.
230V : Indoor Fan at High Speed.
ENTERING AIR DB ID COIL ( °C)
15
20
25
ENTERING AIR
WB OU COIL ( °C)
TH
PI
TH
PI
TH
PI
-10
3.78 1.86 3.64 1.99 3.49 2.09
-7
4.07 1.91 3.92 2.02 3.78 2.12
-2
4.32 1.93 4.18 2.05 4.03 2.17
2
5.26 2.03 5.04 2.16 4.82 2.28
6
7.42 2.18
7.20 2.33
6.95 2.47
10
8.06 2.30 7.85 2.46 7.63 2.63
15
8.71 2.40 8.50 2.59 8.28 2.75
20
9.18 2.47 8.96 2.68 8.71 2.89
*
the above chart includes the weighted deicing infleuence.
LEGEND
TH –
Total Heating Capacity, kW
PI
– Power Input, kW
WB –
Wet Bulb Temp., (
o
C)
DB –
Dry Bulb Temp., (
o
C)
ID
–
Indoor
OU –
Outdoor
5.23
Capacity Correction Factor Due to Tubing Length
5.23.1 Cooling
TOTAL TUBING LENGTH (One Way)
3m
7.5m
10m
15m
20m
25m
30m
40m
50m
1.02
1
0.988
0.975
---
---
---
*
Minimum recommended tubing length between indoor and outdoor units is 3m.
5.23.2 Heating
TOTAL TUBING LENGTH (One Way)
3m
7.5m
10m
15m
20m
25m
30m
40m
50m
1.03
1
0.974
0.965
---
---
---
*
Minimum recommended tubing length between indoor and outdoor units is 3m.
Summary of Contents for GC 22 ST
Page 47: ...4 5 OUTLINE DIMENSIONS Revision Y05 03 Service Manual WNG 4 9 OU8 33 RC ST 4 10 OU10 36 RC ST...
Page 71: ...5 24 PERFORMANCE DATA PRESSURE CURVES Revision Y05 03 Service Manual WNG 5 18 2 Heating...
Page 91: ...5 44 PERFORMANCE DATA PRESSURE CURVES Revision Y05 03 Service Manual WNG 5 33 2 Heating...
Page 95: ...5 48 PERFORMANCE DATA PRESSURE CURVES Revision Y05 03 Service Manual WNG 5 36 2 Heating...