PERFORMANCE DATA & PRESSURE CURVES
Revision Y05-03
Service Manual - WNG
5.19.2
Heating Mode at 7.5m Tubing Connection.
230V : Indoor Fan at High Speed.
ENTERING AIR DB ID COIL ( °C)
15
20
25
ENTERING AIR
WB OU COIL ( °C)
TH
PI
TH
PI
TH
PI
-10 3.72
1.88
3.58
2.00
3.43
2.10
-7
4.00
1.93
3.86
2.03
3.72
2.14
-2
4.25
1.95
4.11
2.07
3.96
2.19
2
5.17
2.04
4.96
2.17
4.74
2.30
6
7.29
2.20
7.08 2.35
6.83 2.50
10
7.93 2.32
7.72 2.48
7.50 2.65
15
8.57 2.42
8.35 2.61
8.14 2.77
20
9.03 2.49
8.81 2.70
8.57 2.91
*
the above chart includes the weighted deicing infleuence.
LEGEND
TH –
Total Heating Capacity, kW
PI
– Power Input, kW
WB –
Wet Bulb Temp., (
o
C)
DB –
Dry Bulb Temp., (
o
C)
ID
–
Indoor
OU –
Outdoor
5.20
Capacity Correction Factor Due to Tubing Length
5.20.1 Cooling
TOTAL TUBING LENGTH
3m
7.5m
10m
15m
20m
25m
30m
40m
50m
1.01
1
0.980
0.970
0.960
---
---
---
---
*
Minimum recommended tubing length between indoor and outdoor units is 3m.
5.20.2 Heating
TOTAL TUBING LENGTH
3m
7.5m
10m
15m
20m
25m
30m
40m
50m
1.02
1
0.990
0.990
0.980
---
---
---
---
*
Minimum recommended tubing length between indoor and outdoor units is 3m.
Summary of Contents for GC 22 ST
Page 47: ...4 5 OUTLINE DIMENSIONS Revision Y05 03 Service Manual WNG 4 9 OU8 33 RC ST 4 10 OU10 36 RC ST...
Page 71: ...5 24 PERFORMANCE DATA PRESSURE CURVES Revision Y05 03 Service Manual WNG 5 18 2 Heating...
Page 91: ...5 44 PERFORMANCE DATA PRESSURE CURVES Revision Y05 03 Service Manual WNG 5 33 2 Heating...
Page 95: ...5 48 PERFORMANCE DATA PRESSURE CURVES Revision Y05 03 Service Manual WNG 5 36 2 Heating...