Applicatio Manual
Universal Interface 4 DIN/NTC EK- CG2-TP
Revisione 1.0.0 - Aggiornato: 04/09/2017
© SBS S.p.A.
– Tutti i diritti riservati
MAEKCG2TP_EN
Pag. 34
When the lock function is enabled, for each input or Input the user can define an action to execute when a lock or
unlock command is received.
Details are shown in the following sections; a resume of all options is shown in the table below
Channel mode
Input type
Behaviour
at locking
Behaviour at
unlocking
independent
send values or
sequences
none
as close or short press
as open or long press
switching
none
off
on
toggle
none
off
on
as previous
coupled
independent
dimming
coupled
independent
scene
none
send first scene
send second scene
independent
shutter or venetian
blind
none
up
down
coupled
\