EFKA SM210A5710
42
TECHNICIAN LEVEL
Parameter
Designation
Unit
max
min
Preset
Ind.
Prg.
No.
165
Oni
0
=
Function Off
1
0
0
C
1
=
The stepping motor stops and/or runs
regardless of the DC drive signal “motor
running” or of any external signal.
Operation and/or s top is determined by the
DC drive speed and/or by the generator
impulses.
If the DC drive speed is <40 RPM, the
stepping motor stops.
If the DC drive speed is >40 RPM, the
stepping motor runs.
171
Sr2
Setting the needle positions:
1E =
Start position 1 (reference position)
degrees
359°
0°
005°
A
2E =
Start Ppsition 2
140°
A
1A =
End position 1
120°
A
2A =
End position 2
340°
A
172
Sr3
Display on V810 control panel:
Pos. 1 to pos. 1A (lefthand arrow above pushbutton 4 On)
Pos. 2 to pos. 2A (righthand arrow above pushbutton 4 On)
172
Sr3
Display on V820 control panel:
Pos. 1 to pos. 1A (lefthand arrow above pushbutton 7 On)
Pos. 2 to pos. 2A (righthand arrow above pushbutton 7 On)
173
Sr3
Checking of the signal outputs and inputs using the
incorporated control panel or the V810/V820 control panels.
01
= Output M8 on socket ST1/24
02
= Output M7 on socket ST1/23
03
= Output M9 on socket ST1/25
04
= Output M3 on socket ST1/27
05...06 = Free
07
= Output M2 on socket ST1/28
08...10 = Free
OFF/ON = By actuating the switches connected to the
control the function of these switches is checked
and displayed with “ON/OFF”.
179
Sr5
Program number of the control with index and
identification number. The data will be displayed in
succession by pressing a pushbutton.
Display example on the V810 control panel:
After calling up the parameter number
Pressing pushb. E
Display [o] blinking
Pressing pushb. >>
Program no./index
Pressing pushb. E
Identification no. (1-6)
Pressing pushb. E
Identification no. (7-8)
Pressing pushb. P
Next parameter
Display example on the V820 control panel:
After calling up the parameter number
Pressing pushb. E
Display [o] blinking
Pressing pushb. >>
Program no./index
Pressing pushb. E
Identification no. (1-8)
Pressing pushb. P
Next parameter