EFKA SM210A5710
45
SUPPLIER LEVEL
Parameter
Designation
Unit
max
min
Preset
Ind.
Prg.
No.
270
bAu
---
=
Automatic baud rate increase from the
6500
0096
---
A
preset baud rate of 9600 onwards
0096 =
Baud rate
9600 baud
0192 =
Baud rate
19200 baud
0312 =
Baud rate
31200 baud
0384 =
Baud rate
38400 baud
0416 =
Baud rate
41600 baud
0560 =
Baud rate
56000 baud
1250 =
Baud rate
125000 baud
3125 =
Baud rate
312500 baud
6500 =
Baud rate
650000 baud
271
cot
0
=
No remote station
2
0
2
A
1
=
Drive is master
2
=
Drive is slave
272
Adv
RS232 address (drive identification)
255
251
254
A
274
bMx
Possibility of setting the maximum adjustment value if
65535
0
65535
A
parameter 290 = “5“. Limitation of stepping motor steps
after reference point adjustment without interfering with
the mechanism.
290
Fam
Mode of operation of the stepping motor control:
9
0
0
A
0
=
Mode manual metering device
Insertable strip for V810 and V820 = 5
1
=
Mode metering device at the start of the seam
Insertable strip for V810 and V820 = 1
2
=
Mode metering device at the seam end
Insertable strip for V810 and V820 = 1
3
=
Mode expander feeding
Insertable strip for V810 and V820 = 2
4
=
No function
5
=
Modus Mehrweitenverstellung
Einschubstreifen für V810 und V820 = 4
6
=
Keine Funktion
7
=
Mode machine for attaching cuff and heel tape
with metering device at the seam end
Insertable strip for V810 and V820 = 1
8
=
Mode puller function 1 (operation with Efka-
controls AB60D, AB62CV, AB220A)
Insertable strip for V810 and V820 = 3
9
=
Mode puller function 2 (operation with other
controls)
Insertable strip for V810 and V820 = 3
291
810
Select insertable strip number for V810 control panel
6
1
5
A
(illustrations of insertable strips see the following
chapter).
292
820
Select insertable strip number for V820 control panel
6
1
5
A
(illustrations of insertable strips see the following
chapter).
293
tF1
Functions of pushbutton A on the V810/V820 control
18
0
3
A
panels (depending on mode)
0
=
No function
1
=
Insert tape
2
=
Switch tape tension, arrow to the right
3
=
Switch tape tension, arrow to the left
4
=
Stepping motor slowly running forward
5
=
Stepping motor slowly running backward
6...18 =
No function
294
tF2
Functions of pushbutton B on the V810/V820 control
18
0
2
A
panels (depending on mode)
Functions of the pushbuttons as with parameter 293
295
nAm
Switching of proximity switches of inputs in2, in7, in8, in9
1
0
0
A