EFKA SM210A5710
40
TECHNICIAN LEVEL
Parameter
Designation
Unit
max
min
Preset
Ind.
Prg.
No.
133
mbL
0
=
No prolongation of the blowing signal after the
3
0
2
A
metering device and sewing foot lifting.
1
=
Prolongation of the blowing signal after the
metering device without sewing foot lifting.
2
=
Prolongation of the blowing signal after the
metering device with sewing foot lifting.
3
=
The blowing signal is emitted only during sewing
foot lifting.
See also parameter 134!
134
t7
Prolongation of the blowing signal emitted
ms
9990
0
0
A
during the metering device. This time is
ineffective if parameter 290 isa set at “5“.
135
t5
Delay time until start of stepping motor for
ms
990
0
300
A
metering device
136
nFd
1
0
1
A
137
nEd
1
0
1
A
Parameter 136
Parameter 137
Functions
0
0
No seam end.
0
1
Initiate end of stepping motor operation by d.c. drive seam end.
1
0
Initiate end of stepping motor operation by d.c. drive trimming
operation
1
1
Determine end of stepping motor operation by last d.c. drive
data record completed.
140
mbS
0
=
Activate tape cutter by means of external
9
0
0
A
pushbutton on input in1. Stepping motor stops.
1
=
Activate tape cutter with pedal in pos. –1.
2
=
Activate tape cutter with pedal in pos. –2.
3
=
The external pushbutton initiates the seam end
when the light barrier function is On on the d.c.
drive. A light barrier must not be connected.
A signal is also transmitted to the d.c. drive.
4
=
Stepping motor stops with light barrier connected,
when changing from covered
è
uncovered.
5
=
Stepping motor stops with light barrier connected,
when changing from uncovered
è
covered.
6
=
A light barrier connected to input in1 stops the
stepping motor, when changing from covered
è
uncovered.
7
=
A light barrier connected to input in1 stops the
stepping motor, when changing from uncovered
è
covered.
8
=
A light barrier connected to input in1 stops the
stepping motor, when changing from covered
è
uncovered. A signal is also transmitted to the
d.c. drive.
9
=
A light barrier connected to input in1 stops the
stepping motor, when changing from uncovered
è
covered. A signal is also transmitted to the
d.c. drive.
The external pushbutton activates the tape cutter at any
setting!
141
rbS
Time for which the stepping motor keeps
ms
9990
0
0
C
running during tape cutter activation
(effective only in modes 1, 2 and 7)
142
t6
Activation time when operating the tape cutter
ms
990
0
300
A
manually at machine standstill