EFKA SM210A5710
32
7.6 Stepping Motor Function “Puller“ (Pa. 290=8 / 9)
Functions
Parameter
Puller operation (operation with one sewing machine control)
290 = 8
Puller operation (without serial communication)
290 = 9
Manual puller operation by means of pushbutton (flip-flop)
141 = 1
Lockstitch mode on the main drive:
142 = 0
Stepping motor runs in reverse direction when the backtacking solenoid is activated
Insertable strip SM 03 for V810 control panel
291 = 3
Insertable strip SM 03 for V820 control panel
292 = 3
Connection of a pushbutton for puller lifting/lowering to socket ST1/10 (in8)
Pushbutton 1 =
Setting the puller reduction ratio 1 or 2
Pushbutton 2 =
Setting the puller reduction ratio 3 or 4
Pushbutton 3 =
Setting the puller reduction ratio 5 or 6
Pushbutton 4 =
Puller function On/Off with display and possibility of setting how long the puller must remain
lifted after the start backtack (see also parameter 150)
Pushbutton A = Pushbutton for manual puller lifting (parallel to input in8)
Pushbutton B =
Selection of puller reduction ratio 1...6
Pushbutton 1...7 =
Setting the puller reduction ratio 1...14
Pushbutton 8 =
Setting the delay stitches until puller lowering
Pushbutton 9 =
Off
è
Puller is not lifted when sewing foot is ON
On
è
Puller is always lifted together with the sewing foot
Pushbutton 0 =
Puller function On/Off with display and possibility of setting how long the puller must
remain lifted after the start backtack (see also parameter 150)
Pushbutton A =
Pushbutton for manual puller lifting (parallel to input in8)
Pushbutton B =
Selection of puller reduction ratio 1...14
variocontrol 810
1
2
3
1
M
2
3
4
5
6
M
M
4
A
KL2453
B
E
1
P
+
6
-
M
SM 03
7
variocontrol 820
2 3
1
1
2
M
M
9
5
6
7
10
8
4
12 13
11
3
4
M
M
6
M
M
5
M
B
M
E
14
1
8
9
0
A
P
+
14
SM 03
KL2454a
-