7.5 Timing Diagram “Machine for Attaching Cuff and Heel Tape with Metering Device at
Functions
Parameter
Machine for attaching cuff and heel tape with metering device at the seam end
290 = 7
Insertable strip SM 01 for V810 control panel
291 = 1
Insertable strip SM 01 for V820 control panel
292 = 1
Connection of a pushbutton for tape cutter to socket ST1/7 (in1)
Connection of a pushbutton for reset to socket ST1/11 (in2)
Connection of a pushbutton for selection of tape speed 4...1 and/or 16...1 to socket ST1/6 (in3)
Connection of a pushbutton for selection of tape speed 1...4 and/or 1...16 to socket ST1/8 (in4)
Connection of a pushbutton for sensor to socket ST1/5 (in5)
Connection of a pushbutton for metering device to socket ST1/12 (in6)
Pushbutton 1 =
-
Setting tape tension 1 or 2 (ratio stepping motor/d.c. drive)
Pushbutton 2 =
-
Setting tape tension 3 or 4 (ratio stepping motor/d.c. drive)
Pushbutton 3 =
-
Setting the number of stitches for the d.c. drive with which the stepping motor runs in
reverse direction
Pushbutton 4 =
-
Setting the number of stepping motor steps for metering device
Pushbutton A = -
Pushbutton for activating the metering device
Pushbutton B =
-
Selection of tape tension 4...1 (parallel with input in3)
Pushbutton 1...8 = -
Setting tape tension 1...16 (ratio stepping motor/d.c. drive)
Pushbutton 9
= -
Setting the number of stitches for the d.c. drive with which the stepping motor runs
in reverse direction
Pushbutton 0
= -
Setting the number of stepping motor steps for metering device
Pushbutton A
= -
Pushbutton for activating the metering device
Pushbutton B
= -
Selection of tape tension 1...16 (parallel with input in3)
1
M
4
3
2
1
4
1
-
P
+
E
variocontrol 810
SM 01
2
1
B
A
4
3
KL2447
7
14
v a r i o c o n t r o l 8 2 0
1
2 3
1
2
4 5
6 7
8 9
10
12
11
13
3
4
5
6
B
E
15 16
1
1
8
9
M
0
A
+
P
1 6
SM 01
KL2448
-