EFKA SM210A5710
39
8.2 Technician Level
Parameter
Designation
Unit
max
min
Preset
Ind.
Prg.
No.
110
SSm
Maximum start/stop speed of the stepping
RPM
400
10
400
A
motor
111
Sn2
Maximum stepping motor speed
RPM
600
10
600
A
112
n1
Fixed stepping motor speed with
RPM
600
1
100
A
asynchronous operation (e. g. tape feeding)
113
n2
Fixed stepping motor speed with manual
RPM
600
1
10
A
operation by means of pushbuttons A and/or B
(with insertable strip 2)
114
n3
Stepping motor speed for regulating the
RPM
600
1
10
C
tape tension correction
(effective only in modes 0, 1 and 2)
120
SnS
From this sewing control speed onwards
RPM
9990
0
0
A
signal M9 is emitted at the stepping motor
control. No signal is emitted if the value is
0000.
130
rPd
Start of meteirng device and/or expander feeding
7
1
1
A
1 = Start only by means of knee switch
2 = Start with pedal in pos. –2 or by means of knee switch
3 = Start with pedal in pos. >1 or by means of knee switch
4 = Start inserting tape with light barrier on B18 or B19
(internal light barrier) when changing from
covered
è
uncovered
, after having actuated pushbutton
tape
cutter
on input in1 (one-time function) or the knee
switch on input in2 (reproducible function).
5 = Start inserting tape with light barrier on B18 or B19
(internal light barrier) when changing from
uncovered
è
covered
, after having actuated pushbutton
tape
cutter
on input in1 (one-time function) or the knee
switch on input in2 (reproducible function).
6 = Start inserting tape with external light barrier or
sensor on input in8 when changing from
uncovered
è
covered
, after having actuated pushbutton
tape
cutter
on input in1 (one-time function) or the knee
switch on input in2 (reproducible function).
7 = Start inserting tape with external light barrier or
sensor on input in8 when changing from
covered
è
uncovered
, after having actuated pushbutton
tape
cutter
on input in1 (one-time function) or the knee
switch on input in2 (reproducible function).
131
bEE
End of metering device at the start of the seam / seam end
3
0
0
A
0 = Metering device by means of number of steps c3
(can be set with parameter 002)
1 = Metering device limited by sensor on input in5
2 = Metering device limited by sensor on input in5
+ run-out stitches c3 backward (can be set with para-
meter 002)
3 = Metering device limited by sensor on input in5
+ run-out stitches c3 forward (can be set with para-
meter 002)
132
Flo
The following functions are possible by setting
1
0
1
A
parameter 290:
0 =
Modes 0, 1, 2, 3, 6, 7, 8 and 9:
Do not lift sewing foot when feeding the tape.
Mode 5:
No reaction to d.c. drive seam end.
1 =
Modes 0, 1, 2, 3, 6, 7, 8 and 9:
Lift sewing foot when feeding the tape.
Mode 5:
Upon initiation of the d.c. drive seam end the
stepping motor starts adjusting the reference point
and performs the function according to the setting
of parameter 153. The function is parallel to
input in7.