EFKA SM210A5710
44
8.3 Supplier Level
Parameter
Designation
Unit
max
min
Preset
Ind.
Prg.
No.
200
GE
Number of increments per revolution of the
incr.
1200
60
120
A
external speed encoder e.g. main drive
AB62CV
= 120
AB220A
= 512
201
PGm
Origin of the position transmitter signals
9
0
6
A
0...5 = No function
6
= Signals G1/G2 are provided by the AB62CV
d.c. drive by way of sockets B18/1 and 6.
Parameter 200 must be set at 120.
7
= Signal G1 is p rovided by an external control.
For intermittent operation the stepping motor is
activated outsiede of the range of position 2.
8
= Function as with setting 7, but the stepping
motor is activated within the range of position 2.
9
= Positions are generated only with G1 and a
synchronous signal on B18/9. Parameter 200
must contain the incr./rev. value of the G1 encoder.
Positions are generated only if a machine running
signal is emitted from input in5.
202
ic
Number of full steps per rotation of the stepping motor
480
60
200
A
203
Efi
Speed operational mode if parameter 290 = 0
1
0
0
A
0
=
Synchronous speed
1
=
Fixed speed
207
ich
On-load current at stepping motor standstill
mA
3000
0
100
A
208
ir
On-load current when the stepping motor is
mA
3000
100
1000
A
running
220
d01
Percental adaptation of the stepping motor
%
200
0
100
A
speed from 700 RPM onwards
221
d02
Percental adaptation of the stepping motor
%
200
0
100
A
speed from 1400 RPM onwards
222
d03
Percental adaptation of the stepping motor
%
200
0
100
A
speed from 2100 RPM onwards
223
d04
Percental adaptation of the stepping motor
%
200
0
100
A
speed from 2800 RPM onwards
224
d05
Percental adaptation of the stepping motor
%
200
0
100
A
speed from 3500 RPM onwards
225
d06
Percental adaptation of the stepping motor
%
200
0
100
A
speed from 4200 RPM onwards
226
d07
Percental adaptation of the stepping motor
%
200
0
100
A
speed from 4900 RPM onwards
227
d08
Percental adaptation of the stepping motor
%
200
0
100
A
speed from 5600 RPM onwards
228
d09
Percental adaptation of the stepping motor
%
200
0
100
A
speed from 6300 RPM onwards
229
d10
Percental adaptation of the stepping motor
%
200
0
100
A
speed from 7000 RPM onwards
230
c7
Correction factor when switching to fast tape feeding
9999
0
25
A
231
c8
Correction factor when switching to fast slow feeding
9999
0
90
A