background image

EFKA DA320G5351 

32

 

Supplier Level 

 

Code no.    311 with control operation 
Code no.  3112 with control panel operation 

 

Parameter   Designation 

Unit 

Limits 

Preset  for 

Ind.

  

 

 

   

 

max  min 100

 220

  

680

 1000

   

283 

LSP  Function “machine run blockage” 

 

 

1  A 

  

Function 

Off 

 

  1  =  Blockage 1, without positioning 

 

  2  =  Blockage 2, with positioning 

284 

StP  Start and end backtack can be interrupted with 

 

0  A 

 

  pedal in position 0 (neutral) On/Off 

287 

dbA  Speed limitation DB3000 (n11) for manual   

 

0  A 

  

backtack 

 

  0  =  Speed limitation Off  

 

  1  =  Speed limitation On 

288 

n9  Speed limitation (n9) for manual  

RPM 

3000 

200  1700 

400 

 

800  1200  A **) 

  

ornamental 

backtack 

289 

n11  Speed limitation (n11) DB3000 

RPM 

6000 

500  3000 

500 

  1700  3000  A **) 

291 

810  Select slide-in strip number for the V810 control 

 

1  A 

  

panel 

 

292 

820  Select slide-in strip number for the V820 control 

10 

 

1  A 

  

panel 

 

293 tF1 

Selection of the input function using the  (A)  

19  0 17 17   17  17 

 

 

key “F1” on the V810/V820 control panel

 

 

  0 

= No function  

 

  1 

= Needle up/down  

 

  2 

= Needle up  

 

  3 

= Single stitch (basting stitch) 

  

Full 

stitch 

 

  5 

= Needle to position 2 

 

  6 

= Output A, if parameter 250 > 0 

 

  7 

= Output B, if parameter 255 > 0 

 

  8 

= Operation in the direction of rotation 

 

  9 

= Operation in the opposite direction of 

  

 

 

rotation 

 

  10...12 = No function  

 

  13 

= High lift for walking foot with speed  

 

   

  limitation n10 (operational mode not stored) 

 

  14 

= High lift for walking foot with speed  

 

   

  limitation n10 (operational mode stored) 

  

15 

No 

function 

 

  16 

= Intermediate backtack  

 

  17 

= Backtack suppression / recall 

  

18 

No 

function 

 

  19 

= Reset bobbin thread monitor  

294 tF2 

Selection of the input function using the

  

(B)

  19 0 1 1   1  1 

 

 

key “F2” on the V810/V820 control panel

 

 

  Functions of the key as with parameter 293 

297 

tFL  Time monitoring of sewing foot lift 

sec 

250 

 

180 

0  A 

 

  (monitoring off at “0“)  

298 

EF-  Upper limit (pa. 204) ON period for 

100 

100 

100 

 

100 

100  A 

 

  sewing foot lift 1...100 

299 

EV-  Upper limit (pa. 213) ON period for  

100 

100 

100 

 

100 

100  A 

  

backtacking 

1...100 

 

 

**)     When programming the 3-digit or 4-digit control parameter values (without control panel), the 2-digit or 3-digit 

value displayed must be multiplied by 10.  

 

Summary of Contents for DA320G5351

Page 1: ...CONTROL DA320G5351 P E I 0 K L2334a LIST OF PARAMETERS CONNECTION DIAGRAM TIMING DIAGRAMS No 402311 English FRANKL KIRCHNER EFKA OF AMERICA INC EFKA ELECTRONIC MOTORS GMBH CO KG SINGAPORE PTE LTD...

Page 2: ...ket Connectors 6 3 1 Position of Operating Elements and Displays 6 3 2 Position of the Socket Connectors 7 3 3 Connection Diagram 8 3 4 Connection of a Sewing Light with Transformer 10 4 Timing Diagra...

Page 3: ...n Routine SIR The Fast Installation Routine SIR passes through all parameters necessary for programming the functional sequence and the positions Input parameter 500 Parameter for direction of motor r...

Page 4: ...trimming On Off Decrease of the value indicated in the programming mode S5 key Basic position 1 or 2 Shift key in the programming mode LED1 Indicator for single start backtack LED2 Indicator for doub...

Page 5: ...encoder IPG001 EFKANET Adapter cord 1113229 in case of multiple assignment B41 Socket for motor power supply B80 Socket for actuator B776 Socket for V810 V820 control panel ST2 Socket for solenoid in...

Page 6: ...M5 Output B POS1 Position 1 in7 DB2000 M6 Output A POS2 Position 2 in8 DB3000 M7 LED lefthand thread monitor GEN Generator impulses in9 External light barrier M8 LED backtack suppression recall R N EX...

Page 7: ...barrier module HSM001 Hall sensor module IPG Pulse encoder EB Actuator Pedal step 2 1 0 1 2 3 4 5 6 7 8 9 10 11 12 Input A L L H H H L L H H L L H H L L H Input B L H H L L L H H H H L L L L H H Inpu...

Page 8: ...through the cable bushing Area B Connect strands with clamp on the printed circuit board Insert earth lead into plug in device on the housing Close and screw connect the housing Mount the control unit...

Page 9: ...ck speed 113 n7 Trimming speed 116 c2 Start backtack stitches forward 000 c1 Start backtack stitches backward 001 c3 End backtack stitches backward 002 c4 End backtack stitches forward 003 t8 Start ba...

Page 10: ...speed 111 n3 Start backtack speed 112 n4 End backtack speed 113 n7 Trimming speed 116 c1 Start backtack stitches backward 001 c3 End backtack stitches backward 002 iFA Activation angle of the thread...

Page 11: ...speed 110 n2 Maximum speed 111 n3 Start backtack speed 112 n4 End backtack speed 113 n6 Softstart speed 115 n7 Trimming speed 116 c1 Start backtack stitches backward 001 c3 End backtack stitches backw...

Page 12: ...compensating stitches 004 iFA Activation angle of the thread trimmer 190 FSA Thread tension release switch off delay 191 FSE Thread tension release activation angle 192 tFA Stop time for thread trimm...

Page 13: ...speed 141 2 n4 End backtack speed 113 n7 Trimming speed 116 n12 Automatic speed for stitch counting 118 c3 End backtack stitches backward 002 c4 End backtack stitches forward 003 Stc Stitches of the s...

Page 14: ...imum speed 111 n3 Start backtack speed 112 n4 End backtack speed 113 n7 Trimming speed 116 SAv Number of start ornamental backtack stitches forward 080 SAr Number of start ornamental backtack stitches...

Page 15: ...2 Maximum speed 111 n3 Start backtack speed 112 n4 End backtack speed 113 n7 Trimming speed 116 n10 High lift walking speed 117 c2 Start backtack stitches forward 000 c1 Start backtack stitches backwa...

Page 16: ...or walking foot only if parameter 250 or 255 11 oprational mode stored On operational mode not stored Off 4 Needle cooling On Off only if parameter 185 1 5 Signals A1 and or A2 On Off with slide in st...

Page 17: ...c Bobbin thread monitor function is deactivated 1 sec Counter is set to preset value 087 Intermediate backtack with counted stitches 255 0 0 0 0 0 A stitches At setting 0 normal intermediate backtack...

Page 18: ...rS End backtack synchronization speed RPM 3000 200 1700 400 800 500 A 125 n2A Start backtack speed 2 RPM 3000 200 600 600 600 600 A only if parameter 284 ON 126 n2E End backtack speed 2 RPM 3000 200 6...

Page 19: ...ut influence by the pedal machine stop by pressing the pedal to the basic position 2 Limited speed controllable by the pedal up to the set limit parameter 118 3 At fixed speed parameter 118 can be int...

Page 20: ...015 357 A for changing the values turn handwheel or press the key Press the P key twice Settings are completed 172 Sr3 Display on the control Pos 1 to 1A LED 7 lights up Pos 2 to 2A LED 8 lights up 17...

Page 21: ...tor rotation On Off 1 0 0 0 0 0 A 183 t05 Switch off delay of needle cooling after ms 2550 0 2500 2500 2500 2500 A stop 184 chP Minimum number of stitches for high lift stitches 254 0 0 0 0 0 A for wa...

Page 22: ...reduction in the seam and after thread trimming Off 1 Thread tension release and thread tension reduction in the seam during sewing foot lifting On 2 Thread tension release and thread tension reducti...

Page 23: ...ing power for backtacking 1 100 pa 299 1 50 50 50 50 A 1 low holding power 100 high holding power 215 Zrv 0 Last counted forward section in the start 1 0 1 1 1 1 A backtack OFF 1 Last counted forward...

Page 24: ...eter 131 29 Single stitch with stitch length switching 30 Emergency stop 31 38 No function 39 Switch to the next pattern in TEACH IN 40 Switch back to the previous pattern in TEACH IN 41 45 No functio...

Page 25: ...speed limitation 3 Fullness control without speed limitation 4 Single stitch with stitch length switching 5 Lift lower roller 6 Lift lower fabric endstop 7 Thread tension reduction 8 Manual edge trimm...

Page 26: ...ing to setting of parameter 161 14 Handwheel runs in the opposite direction of rotation according to setting of parameter 161 256 bFA Output B A 32 and LED B A 31 after thread 1 0 0 0 0 0 A trimming 0...

Page 27: ...FL 0 Sewing foot lowers when the handwheel 1 0 1 1 1 1 A rotates 1 The functions pedal in pos 1 or automatic sewing foot lift remain effective 267 kFk 0 The edge trimmer remains On independently 1 0 0...

Page 28: ...PGm Selection according to the position sensors 5 0 0 0 0 0 A Setting of socket B18 see chapter Connection Diagram 0 Function as in table on previous page 1 Setting the sensor to position 2 Set posit...

Page 29: ...100 100 A machine shaft calculation formula see instruction manual Attention The transmission ratio should be determined and indicated as precisely as possible 280 SEL Display of the select resistor v...

Page 30: ...810 V820 control panel 0 No function 1 Needle up down 2 Needle up 3 Single stitch basting stitch 4 Full stitch 5 Needle to position 2 6 Output A if parameter 250 0 7 Output B if parameter 255 0 8 Oper...

Page 31: ...9 302 tr1 Starting point for signal A1 3 0 0 0 0 0 A 0 Start at the beginning of the seam 1 Start of the signal triggered by light barrier sensing 2 Start of the signal when the drive stops at the sea...

Page 32: ...stops at the seam end 3 Start from light barrier covered onwards at the beginning of the seam 313 do2 Delay of signal A2 2 0 1 1 1 1 A 0 No delay until signal On 1 Delay over time until signal On 2 De...

Page 33: ...0 0 0 319 309 NA 100 100 NE 10 10 10 10 100 10 100 100 100 100 10 100 LS 0256 B I LD4 100 P 0 FA E NA Start of seam LS Light barrier uncovered or covered at the seam end LS D Light barrier uncovered...

Page 34: ...1 3 3 3 0 3 3 2 1 1 3 3 0 1 0 2 1 0 2 2 0 0 2 0 0 301 Parameter 311 A1 A2 0 0 1 0 0 0 0 0 0 1 1 0 3 0 0 302 312 303 313 10 0 10 0 10 0 0 0 0 10 0 100 0 0 0 0 100 100 100 0 0 0 0 0 0 100 0 100 0 0 0 0...

Page 35: ...E keys are Off 1 P key is On and E key is Off 2 P key is Off and E key is On 3 P and E keys are On 327 EPm Disabling the keys on the control panels 1 0 1 1 1 1 A 0 and keys are Off 1 and keys are On...

Page 36: ...code number or parameter number or to last or to last display InFo F1 input parameter number parameter number Serious Condition On the control On the V810 On the V820 Signification E1 InF E1 InF E1 Th...

Page 37: ...rol panel 1 2 1 2 1 2 1 2 F F F F F2 F2 F2 F2 F2 INSERT DELETE F1 INSERT DELETE F1 INSERT DELETE F1 F1 INSERT DELETE F1 9 10 K L2256e 7 8 6 R R R R R F F F F F2 F2 F2 F1 F1 F1 3 4 5 1 2 Note When chan...

Page 38: ...fka net http www efka net OF AMERICA INC 3715 NORTHCREST ROAD SUITE 10 ATLANTA GEORGIA 30340 PHONE 770 457 7006 TELEFAX 770 458 3899 email efkaus bellsouth net ELECTRONIC MOTORS SINGAPORE PTE LTD 67 A...

Reviews: