EFKA DA320G5351
30
Supplier Level
Code no. 311 with control operation
Code no. 3112 with control panel operation
= 0V
OUT
OUT
OUT
OUT
ST2
IN
POS1
ST2/21
POS2
POS2
ST2/20
POS1
ST2/21
ST2/20
POS2
ST2/21
POS1
ST2/20
POS1
ST2/20
POS
B18/7
ST2/21
POS2
SEN
= high
0 2 5 6 / S EN - 1
Pa 271
Pa 271
Pa 271
Pa 271
360°
27
0 =
1
27
0 =
3
27
0 =
4
27
0 =
2
+5V
0V
OUT (position window) = npn transistor (emitter to 0V) is conductive.
Width of position window cannot be adjusted!
Parameter Designation
Unit
Limits
Preset for
Ind.
max min 100
Ω
220
Ω
680
Ω
1000
Ω
270 PGm Selection according to the position sensors.
5
0
0
0
0
0 A
Setting of socket B18 see chapter “Connection
Diagram”
0 = Function as in table on previous page!
1 = Setting the sensor to position 2.
Set position 1 using parameter 171, starting
from trailing edge position 2.
2 = Setting the sensor to position 2.
Set position 1 using parameter 171, starting
from leading edge position 2.
3 = Setting the sensor to position 1.
Set position 2 using parameter 171, starting
from trailing edge position 1.
4 = Setting the sensor to position 1.
Set position 2 using parameter 171, starting
from leading edge position 1.
5 = No position sensor available. The drive stops
unpositioned. The thread trimmer function is