EFKA DA320G5351
38
6 Error
Displays
General Information
On the control
On the V810
On the V820
Signification
A1
InF A1
InF A1
Pedal not in neutral position, when turning
the
machine
on
A2
-StoP- blinking
-StoP- bl Machine run blockage
symbol
display
A3
InF A3
InF A3
Reference position is not set
A5
InF A5
InF A5
Emergency run, identification of an invalid
machine
select
Programming Functions and Values (Parameters)
On the control
On the V810
On the V820
Signification
Returns to 000
Returns to 0000
Like V810 +
Wrong code number or parameter number
or to last
or to last
display InFo F1
input
parameter number parameter
number
Serious Condition
On the control
On the V810
On the V820
Signification
E1
InF E1
InF E1
The external pulse encoder e.g. IPG... is
defective or not connected.
E2
InF E2
InF E2
Line voltage too low, or time between power off
and power on too short.
E3
InF E3
InF E3
Machine blocked or does not reach the desired
speed.
E4
InF E4
InF E4
Control disturbed by deficient grounding or
loose
contact.
E9
InF E9
InF E9
EEPROM defective.
Hardware Disturbance
On the control
On the V810
On the V820
Signification
H1
InF H1
InF H1
Commutation transmitter cord or frequency
converter
disturbed.
H2
InF H2
InF H2
Processor disturbed