EFKA
DA320G5351
21
Technician Level
Code no. 190 with control operation
Code no. 1907 with control panel operation
Parameter Designation
Unit
Limits
Preset for
Ind.
max min 100
Ω
220
Ω
680
Ω
1000
Ω
133
LSE Thread trimming operation, when completing the
1
0
1
1
1
1 A
seam after light barrier sensing On/Off
134
SSt
Softstart
On/Off
1 0 1 1 1 1
A
135
SrS Ornamental backtack On/Off
1
0
0
0
0
0 A
136
FAr 0 = Trimming stitch forward and thread wiper
6
0
5
0
1
0 A
function
On
1 = Trimming stitch backward and thread wiper
function
On
2 = Trimming stitch forward with short trimmer
signal instead of a thread wiper
3 = No function
4 = No function
5 = Thread clamp with trimming stitch backward
6 = Thread clamp with trimming stitch forward
137
SLU Stitch length during backtack
1
0
1
1
0
0 A
0
=
long
stitches
1
=
normal
stitches
138
hPr 0 = High lift for walking foot
1
0
0
0
0
0 A
operational mode not stored
1 = High lift for walking foot
operational
mode
stored
139
nIS Display of machine speed On/Off
1
0
0
0
0
0 A
141 SGn Speed status for the seam with stitch counting
4
0
1
1
1
1 A
0 = Speed controllable by the pedal up to the set
maximum speed (parameter 111)
1 = Fixed speed (parameter 118) without
influence by the pedal (machine stop by
pressing the pedal to the basic position)
2 = Limited speed controllable by the pedal up to
the set limit (parameter 118)
3 = At fixed speed (parameter 118) can be
interrupted by full heelback
4 = At fixed speed (parameter 110) can be
interrupted by full heelback.
142
SFn Speed status for the free seam and for the seam
3
0
0
0
0
0 A
with light barrier
0 = Speed controllable by the pedal up to the set
maximum speed (parameter 111)
1 = Fixed speed (parameter 118) without
influence by the pedal (machine stop by
pressing the pedal to the basic position)
2 = Limited speed controllable by the pedal up to
the set limit (parameter 118)
3 = At fixed speed (parameter 118) can be
interrupted by full heelback
145
StL Normal/long stitches with/without speed limitation.
2
0
0
0
0
0 A
Key on input in1...i10 = 22.
0 = Normal/long stitches without speed limitation
1 = Normal/long stitches with speed limitation
(DB2000)
2 = Normal/long stitches with speed limitation
(DB3000)
150
t8 Stitch correction of the double start
ms
500
0
0
0
0
0 A
backtack (prolongation of the stitch
regulator ON period / not effective with
ornamental backtack)
151
t9 Stitch correction of the double end
ms
500
0
0
0
0
0 A
backtack (prolongation of the stitch
regulator ON period / not effective with
ornamental backtack)
152
thP Run-out time of the high lift walking speed ms
500
80
100
100
100
100 A