EFKA
DA320G5351
25
5.3 Supplier
Level
Code no. 311 with control operation
Code no. 3112 with control panel operation
Parameter Designation
Unit
Limits
Preset for
Ind.
max min 100
Ω
220
Ω
680
Ω
1000
Ω
200
t1 Delay until speed release after start
ms
500
0
50
50
50
50 A
backtack
201
t2 Sewing foot lift switch-on delay with half
ms
500
20
80
80
80
80 A
heelback
202
t3 Start delay after disabling the sewing foot ms
500
0
80
80
120
80 A
lift
signal
203
t4 Time of full power of sewing foot lifting
ms
600
0
200
200
200
200 A
204
t5 Holding power for sewing foot lifting
%
pa. 298
1
40
40
40
40 A
1...100%
1%
low holding power
100%
high holding power
205
t6 Thread wiper time
ms
2550
0
100
100
100
100 A**)
206
t7 Delay from end of thread wiper until
ms
800
0
50
50
30
30 A
sewing foot lifting On
207
br1 Braking effect when modifying the preset value
55
1
20
20
20
20 A
≤
4 stages
208
br2 Braking effect when modifying the preset value
55
1
30
30
30
30 A
≥
5 stages
210
tSr Stop time for switching the stitch regulator ms
500
0
100
270
150
100 A
in the ornamental backtack
212
t10 Time of full power of backtacking
ms
600
0
200
200
200
200 A
213
t11 Holding power for backtacking 1...100%
%
pa. 299
1
50
50
50
50 A
1%
low holding power
100%
high holding power
215
Zrv 0 = Last counted forward section in the start
1
0
1
1
1
1 A
backtack
OFF
1 = Last counted forward section in the start
backtack
ON
216
FLS 0 = Fast disabling of sewing foot lift OFF
1
0
1
1
1
1 A
1 = Fast disabling of sewing foot lift ON
219
br3 Positioning power at stop of the drive
55 1 10 10 10 10
A
220
ALF Accelerating power of the drive
55
1
20
20
20
20 A
221
dGn Speed gate 1
RPM
990
50
100
100
100
100 A
222
tGn Speed gate damping period
ms
990
0
120
120
120
120 A
223
dG2 Speed gate 2
RPM
6000
200 1300 1600
1600 1600 A**)
224
dGF Speed gate 2 On/Off
1
0
1
1
1
1 A
240 in1
Selection of the input functions on socket A/7
69 0 13 13 13 13
A
for
input 1
0
=
No
function
1
=
Needle
up/down
2
=
Needle
up
3 = Single stitch (basting stitch)
4
=
Full
stitch
5 = Needle to position 2
6 = Machine run blockage effective with open
contact
7 = Machine run blockage effective with closed
contact
8 = Machine run blockage unpositioned effective
with
open
contact
9 = Machine run blockage unpositioned effective
with
closed
contact
10 = Automatic speed n12 without pedal
11 = Limited speed n12 pedal controlled
**) When programming the 3-digit or 4-digit control parameter values (without control panel), the 2-digit or 3-digit
value displayed must be multiplied by 10.