background image

EFKA DA320G5351 

16

 

Machine run with ornamental backtack

 

 

0

POS.2

A/28

A/27

A/36

A/37

A/34

A/35

A/21

M2

M3

M4

M1

VR

FL

(FSPL)

(ML)

(FW)

(FA)

t3

A/20

POS.1

-

0

n

+

-1
-2

1/2

1

SAv

tSr

SAr

tSr

SAr t1

n1

n1

1 2

3

2

1

n3

n3

n3

3

2

1

3

0 2 6 7 / LAU FZ VR

SEv

tSr

tSr

SEr

n2

n1

n1

n4

2

1

3

2

1

n4

FSA

FSE

tFA

iFA

t6

n7

n7

3

 

 
 
 

Mark Function 

  Parameter 

Control  V810 V820 

 

Double start backtack 

On   

Key S2  

Key 1  

Key 1  

 

Double end backtack 

On   

Key S3  

Key 2  

Key 4  

 

Ornamental backtack 

 

135 = 1 

n1 Positioning 

speed 

 

110 

n2 Maximum 

speed 

 

111 

n3 

Start backtack speed 

 

112 

n4 

End backtack speed 

 

113 

n7 Trimming 

speed 

 

116 

SAv 

Number of start ornamental backtack stitches forward   

080 

SAr 

Number of start ornamental backtack stitches backward  

081 

SEr 

Number of end ornamental backtack stitches backward  

082 

SEv 

Number of end ornamental backtack stitches forward   

083 

iFA 

Activation angle of the thread trimmer 

 

190 

FSA 

Thread tension release switch-off delay 

 

191 

FSE 

Thread tension release activation angle 

 

192 

tFA 

Stop time for thread trimmer 

 

193 

t1 

Delay until speed release after start backtack 

 

200 

t3 

Start delay from lifted sewing foot 

 

202 

t6 

Thread wiper ON period 

 

205 

tSr 

Stop time for ornamental backtack 

 

210 

 
 
 
 

Summary of Contents for DA320G5351

Page 1: ...CONTROL DA320G5351 P E I 0 K L2334a LIST OF PARAMETERS CONNECTION DIAGRAM TIMING DIAGRAMS No 402311 English FRANKL KIRCHNER EFKA OF AMERICA INC EFKA ELECTRONIC MOTORS GMBH CO KG SINGAPORE PTE LTD...

Page 2: ...ket Connectors 6 3 1 Position of Operating Elements and Displays 6 3 2 Position of the Socket Connectors 7 3 3 Connection Diagram 8 3 4 Connection of a Sewing Light with Transformer 10 4 Timing Diagra...

Page 3: ...n Routine SIR The Fast Installation Routine SIR passes through all parameters necessary for programming the functional sequence and the positions Input parameter 500 Parameter for direction of motor r...

Page 4: ...trimming On Off Decrease of the value indicated in the programming mode S5 key Basic position 1 or 2 Shift key in the programming mode LED1 Indicator for single start backtack LED2 Indicator for doub...

Page 5: ...encoder IPG001 EFKANET Adapter cord 1113229 in case of multiple assignment B41 Socket for motor power supply B80 Socket for actuator B776 Socket for V810 V820 control panel ST2 Socket for solenoid in...

Page 6: ...M5 Output B POS1 Position 1 in7 DB2000 M6 Output A POS2 Position 2 in8 DB3000 M7 LED lefthand thread monitor GEN Generator impulses in9 External light barrier M8 LED backtack suppression recall R N EX...

Page 7: ...barrier module HSM001 Hall sensor module IPG Pulse encoder EB Actuator Pedal step 2 1 0 1 2 3 4 5 6 7 8 9 10 11 12 Input A L L H H H L L H H L L H H L L H Input B L H H L L L H H H H L L L L H H Inpu...

Page 8: ...through the cable bushing Area B Connect strands with clamp on the printed circuit board Insert earth lead into plug in device on the housing Close and screw connect the housing Mount the control unit...

Page 9: ...ck speed 113 n7 Trimming speed 116 c2 Start backtack stitches forward 000 c1 Start backtack stitches backward 001 c3 End backtack stitches backward 002 c4 End backtack stitches forward 003 t8 Start ba...

Page 10: ...speed 111 n3 Start backtack speed 112 n4 End backtack speed 113 n7 Trimming speed 116 c1 Start backtack stitches backward 001 c3 End backtack stitches backward 002 iFA Activation angle of the thread...

Page 11: ...speed 110 n2 Maximum speed 111 n3 Start backtack speed 112 n4 End backtack speed 113 n6 Softstart speed 115 n7 Trimming speed 116 c1 Start backtack stitches backward 001 c3 End backtack stitches backw...

Page 12: ...compensating stitches 004 iFA Activation angle of the thread trimmer 190 FSA Thread tension release switch off delay 191 FSE Thread tension release activation angle 192 tFA Stop time for thread trimm...

Page 13: ...speed 141 2 n4 End backtack speed 113 n7 Trimming speed 116 n12 Automatic speed for stitch counting 118 c3 End backtack stitches backward 002 c4 End backtack stitches forward 003 Stc Stitches of the s...

Page 14: ...imum speed 111 n3 Start backtack speed 112 n4 End backtack speed 113 n7 Trimming speed 116 SAv Number of start ornamental backtack stitches forward 080 SAr Number of start ornamental backtack stitches...

Page 15: ...2 Maximum speed 111 n3 Start backtack speed 112 n4 End backtack speed 113 n7 Trimming speed 116 n10 High lift walking speed 117 c2 Start backtack stitches forward 000 c1 Start backtack stitches backwa...

Page 16: ...or walking foot only if parameter 250 or 255 11 oprational mode stored On operational mode not stored Off 4 Needle cooling On Off only if parameter 185 1 5 Signals A1 and or A2 On Off with slide in st...

Page 17: ...c Bobbin thread monitor function is deactivated 1 sec Counter is set to preset value 087 Intermediate backtack with counted stitches 255 0 0 0 0 0 A stitches At setting 0 normal intermediate backtack...

Page 18: ...rS End backtack synchronization speed RPM 3000 200 1700 400 800 500 A 125 n2A Start backtack speed 2 RPM 3000 200 600 600 600 600 A only if parameter 284 ON 126 n2E End backtack speed 2 RPM 3000 200 6...

Page 19: ...ut influence by the pedal machine stop by pressing the pedal to the basic position 2 Limited speed controllable by the pedal up to the set limit parameter 118 3 At fixed speed parameter 118 can be int...

Page 20: ...015 357 A for changing the values turn handwheel or press the key Press the P key twice Settings are completed 172 Sr3 Display on the control Pos 1 to 1A LED 7 lights up Pos 2 to 2A LED 8 lights up 17...

Page 21: ...tor rotation On Off 1 0 0 0 0 0 A 183 t05 Switch off delay of needle cooling after ms 2550 0 2500 2500 2500 2500 A stop 184 chP Minimum number of stitches for high lift stitches 254 0 0 0 0 0 A for wa...

Page 22: ...reduction in the seam and after thread trimming Off 1 Thread tension release and thread tension reduction in the seam during sewing foot lifting On 2 Thread tension release and thread tension reducti...

Page 23: ...ing power for backtacking 1 100 pa 299 1 50 50 50 50 A 1 low holding power 100 high holding power 215 Zrv 0 Last counted forward section in the start 1 0 1 1 1 1 A backtack OFF 1 Last counted forward...

Page 24: ...eter 131 29 Single stitch with stitch length switching 30 Emergency stop 31 38 No function 39 Switch to the next pattern in TEACH IN 40 Switch back to the previous pattern in TEACH IN 41 45 No functio...

Page 25: ...speed limitation 3 Fullness control without speed limitation 4 Single stitch with stitch length switching 5 Lift lower roller 6 Lift lower fabric endstop 7 Thread tension reduction 8 Manual edge trimm...

Page 26: ...ing to setting of parameter 161 14 Handwheel runs in the opposite direction of rotation according to setting of parameter 161 256 bFA Output B A 32 and LED B A 31 after thread 1 0 0 0 0 0 A trimming 0...

Page 27: ...FL 0 Sewing foot lowers when the handwheel 1 0 1 1 1 1 A rotates 1 The functions pedal in pos 1 or automatic sewing foot lift remain effective 267 kFk 0 The edge trimmer remains On independently 1 0 0...

Page 28: ...PGm Selection according to the position sensors 5 0 0 0 0 0 A Setting of socket B18 see chapter Connection Diagram 0 Function as in table on previous page 1 Setting the sensor to position 2 Set posit...

Page 29: ...100 100 A machine shaft calculation formula see instruction manual Attention The transmission ratio should be determined and indicated as precisely as possible 280 SEL Display of the select resistor v...

Page 30: ...810 V820 control panel 0 No function 1 Needle up down 2 Needle up 3 Single stitch basting stitch 4 Full stitch 5 Needle to position 2 6 Output A if parameter 250 0 7 Output B if parameter 255 0 8 Oper...

Page 31: ...9 302 tr1 Starting point for signal A1 3 0 0 0 0 0 A 0 Start at the beginning of the seam 1 Start of the signal triggered by light barrier sensing 2 Start of the signal when the drive stops at the sea...

Page 32: ...stops at the seam end 3 Start from light barrier covered onwards at the beginning of the seam 313 do2 Delay of signal A2 2 0 1 1 1 1 A 0 No delay until signal On 1 Delay over time until signal On 2 De...

Page 33: ...0 0 0 319 309 NA 100 100 NE 10 10 10 10 100 10 100 100 100 100 10 100 LS 0256 B I LD4 100 P 0 FA E NA Start of seam LS Light barrier uncovered or covered at the seam end LS D Light barrier uncovered...

Page 34: ...1 3 3 3 0 3 3 2 1 1 3 3 0 1 0 2 1 0 2 2 0 0 2 0 0 301 Parameter 311 A1 A2 0 0 1 0 0 0 0 0 0 1 1 0 3 0 0 302 312 303 313 10 0 10 0 10 0 0 0 0 10 0 100 0 0 0 0 100 100 100 0 0 0 0 0 0 100 0 100 0 0 0 0...

Page 35: ...E keys are Off 1 P key is On and E key is Off 2 P key is Off and E key is On 3 P and E keys are On 327 EPm Disabling the keys on the control panels 1 0 1 1 1 1 A 0 and keys are Off 1 and keys are On...

Page 36: ...code number or parameter number or to last or to last display InFo F1 input parameter number parameter number Serious Condition On the control On the V810 On the V820 Signification E1 InF E1 InF E1 Th...

Page 37: ...rol panel 1 2 1 2 1 2 1 2 F F F F F2 F2 F2 F2 F2 INSERT DELETE F1 INSERT DELETE F1 INSERT DELETE F1 F1 INSERT DELETE F1 9 10 K L2256e 7 8 6 R R R R R F F F F F2 F2 F2 F1 F1 F1 3 4 5 1 2 Note When chan...

Page 38: ...fka net http www efka net OF AMERICA INC 3715 NORTHCREST ROAD SUITE 10 ATLANTA GEORGIA 30340 PHONE 770 457 7006 TELEFAX 770 458 3899 email efkaus bellsouth net ELECTRONIC MOTORS SINGAPORE PTE LTD 67 A...

Reviews: