EFKA
DA320G5351
17
Machine run with high lift for walking foot
(LHP)
M11
A/31
HP
A/7
1
c2
A/21
(FSPL)
(HP)
M2
M3
A/28
A/27
A/36
M5
A/32
M4
M1
VR
FL
A/37
A/34
A/35
(ML)
(FW)
(FA)
t3
n
POS.2
A/20
POS.1
+
-
-2
0
-1
0
1/2
1
t1
c1
cb
n3
3
2
1
3
2
n2
n10
5
4
3
2
1
0
0 2 6 7 / LAU FH U B
c3
tHP
c4
1
n2
0
6
n4
n7
3
2
1
2
tFA
t6
t7
FSA
FSE
iFA
n7
Mark Function
Parameter
Control V810 V820
Double start backtack
On
Key S2
Key 1
Key 1
Double end backtack
On
Key S3
Key 2
Key 4
High lift for walking foot operational mode not stored
138 = 0
Output B high lift for walking foot
255 = 11
n2 Maximum
speed
111
n3
Start backtack speed
112
n4
End backtack speed
113
n7 Trimming
speed
116
n10
High lift walking speed
117
c2
Start backtack stitches forward
000
c1
Start backtack stitches backward
001
c3
End backtack stitches backward
002
c4
End backtack stitches forward
003
thP
High lift walking speed run-out time
152
iFA
Activation angle of the thread trimmer
250
FSA
Thread tension release switch-off delay
191
FSE
Thread tension release activation angle
192
tFA
Stop time for thread trimmer
253
t1
Delay until speed release after start backtack
200
t3
Start delay from lifted sewing foot
202
t6
Thread wiper ON period
205
t7
Sewing foot switch-on delay after thread wiper
206
cb
Number of stitches output B “high lift for walking foot”
258