EFKA
DA320G5351
11
4 Timing
Diagrams
Trimming from full machine run
1
c3
1
c2
(FSPL)
A/36
M2
M3
A/28
A/27
M4
M1
VR
FL
A/37
A/34
A/35
(ML)
(FW)
(FA)
t3
n
+
POS.2
A/21
A/20
POS.1
-
0
-1
-2
0
1/2
1
c1
t8 t1
n3
3
2
1
3
2
n2
0
t9
c4
t6
FSA
iFA
FSE
tFA
n4
n7
3
2
1
2
n7
0 2 6 7 / FALAU F
t5
t4
t7
Mark Function
Parameter
Control V810 V820
Double start backtack with stitch correction
On
Key S2
Key 1
Key 1
Double end backtack with stitch correction
On
Key S3
Key 2
Key 4
n2 Maximum
speed
111
n3
Start backtack speed
112
n4
End backtack speed
113
n7 Trimming
speed
116
c2
Start backtack stitches forward
000
c1
Start backtack stitches backward
001
c3
End backtack stitches backward
002
c4
End backtack stitches forward
003
t8
Start backtack stitch correction
150
t9
End backtack stitch correction
151
iFA
Activation angle of the thread trimmer
190
FSA
Thread tension release switch-off delay
191
FSE
Thread tension release activation angle
192
tFA
Stop time for thread trimmer
193
t1
Delay until speed release after start backtack
200
t3
Start delay from lifted sewing foot
202
t4
Full power of sewing foot lifting
203
t5
Pulsing of sewing foot lifting
204
t6
Thread wiper ON period
205
t7
Sewing foot switch-on delay after thread wiper
206