66
Installation and Service Guide: Color Controller E-45
Replacing parts
4
Replace the printer interface board (see
for the location).
Make sure to install the board mounting bracket screw to secure the board to the chassis. Press down firmly on the top
of the board as you insert the screw.
5
Replace the 10-pin power button cable that connects the printer interface board (J351 connector) and the motherboard
connector (J15).
6
If you reinstalled the old motherboard, reassemble the E-45 and verify its functionality (see
).
7
If you replaced the motherboard with a new motherboard, do the following:
•
Remove the battery (see
•
Wait two minutes to allow the motherboard electrical components to fully discharge.
•
Reinstall the battery.
•
Reassemble the E-45 (see
).
•
Reset the time and date in Setup (see Command WorkStation Help for more information).
Verifying new motherboard installation, and transferring options and BIOS information
After you install a new motherboard and reassemble the system, do the following:
•
Verify all functionality by using the motherboard replacement dongle to enter Service Mode. (Service Mode is not
indicated on the monitor or Fiery QuickTouch panel, but is entered once you power on with a new motherboard
installed and the motherboard replacement dongle installed on a USB port.)
Service Mode is a temporary state that allows you to make sure that the motherboard solves the problem that you are
troubleshooting. Service Mode is exited automatically when you expend the motherboard replacement dongle to
transfer options to the new motherboard (see
Note:
Features of Fiery Impose-Compose are not available while in Service Mode.
Important:
Make sure that unused connector panel slots are covered with slot covers. Uncovered slots reduce air
flow and may cause the E-45 to overheat.