18
User Manual
MN040024EN
Effective November 2016
DX-NET-ETHERNET2-2 fi eld bus connection
EtherNet/IP for variable frequency drive DE1/DC1
EATON
www.eaton.com
DE1 parameter mapping
Table 11. Class 0x04 Assembly (Read/write max parameters from Instance)
Drive
Mode
Type
Inst.
Read
service
Max
supported len
Write
service
Max
supported len
Para.
Description
—
Field bus command
R/W
WORD
1
0x18
30
0x19
4
—
Field bus speed reference value
R/W
S16
2
0x18
29
0x19
3
—
Reserved R/W
—
3
0x18
28
0x19
2
—
Modbus ramp time
R/W
U16
4
0x18
27
0x19
1
—
Reserved
R
—
5
0x18
26
—
0
—
Status and fault word
R
—
6
0x18
25
—
0
—
Field bus actual speed
R
S16
7
0x18
24
—
0
P00-05
Motor current
R
U16
8
0x18
23
—
0
—
Reserved
R
—
9
0x18
22
—
0
—
Reserved
R
—
10
0x18
21
—
0
P00-04
DI status
R
Binary code
11
0x18
20
—
0
P00-20
Type
R
WORD
12
0x18
19
—
0
P00-20
Power
R
U16
13
0x18
18
—
0
P00-20
Voltage level
R
U16
14
0x18
17
—
0
P00-18
Control section software version
R
WORD
15
0x18
16
—
0
P00-18
Power section software version
R
WORD
16
0x18
15
—
0
P00-20
Variable frequency drive recognition
R
WORD
17
0x18
14
—
0
—
Reserved
R
—
18
0x18
13
—
0
—
Reserved
R
—
19
0x18
12
—
0
P00-01
Value AI1
R
U16
20
0x18
11
—
0
P00-02
Value AI2
R
U16
21
0x18
10
—
0
P00-03
Reference input speed
R
S16
22
0x18
9
—
0
P00-08
DC link voltage
R
U16
23
0x18
8
—
0
P00-09
Temperature in power section
R
S16
24
0x18
7
—
0
P00-10
DE1 operating time
R
—
25
0x18
6
—
0
—
DE1 operating time
R
—
26
0x18
5
—
0
P00-12
DE1 operating time since the last fault message
R
—
27
0x18
4
—
0
—
DE1 operating time since the last fault
R
—
28
0x18
3
—
0
—
Reserved
R
—
29
0x18
2
—
0
—
Reserved
R
—
30
0x18
1
—
0
1
Maximum Output Frequency
R/W
U16
129
0x18
41
0x19
0
2
Minimum output frequency
R/W
U16
130
0x18
40
0x19
0
3
Accel ramp time
R/W
U16
131
0x18
39
0x19
0
4
Decel ramp time
R/W
U16
132
0x18
38
0x19
0
5
Stop mode select
R/W
U16
133
0x18
37
0x19
0
6
Energy save
R/W
U16
134
0x18
36
0x19
0
7
Motor rated voltage
R/W
U16
135
0x18
35
0x19
0
8
Motor rated current
R/W
U16
136
0x18
34
0x19
0
9
Motor rated frequency
R/W
U16
137
0x18
33
0x19
0
10
Motor rated speed
R/W
U16
138
0x18
32
0x19
0
11
Boost voltage value
R/W
U16
139
0x18
31
0x19
0
12
Process data access
R/W
U16
140
0x18
30
0x19
0
13
Trip log
R/W
U16
141
0x18
29
0x19
0
14
Access code
R/W
U16
142
0x18
28
0x19
0
15
Function of the control terminals
R/W
U16
143
0x18
27
0x19
0
16
Analog input AI1, signal range
R/W
U16
144
0x18
26
0x19
0
17
Analog input AI1, gain (scaling)
R/W
U16
145
0x18
25
0x19
0
18
Analog input AI1, inversion
R/W
U16
146
0x18
24
0x19
0
19
Digital input DI3, Logic
R/W
U16
147
0x18
23
0x19
0