DX-NET-ETHERNET2-2 fi eld bus connection
EtherNet/IP for variable frequency drive DE1/DC1
EATON
www.eaton.com
Table 12. Class 0x44 Modbus (Read/Write indicted number of parameters from Instance)
Drive
Mode
Type
Inst.
Read
service
Max
supported len
Write
service
Max
supported len
Para.
Description
—
Field bus command
R/W
WORD
1
0x4E
30
0x50
4
—
Field bus speed reference value
R/W
S16
2
0x4E
29
0x50
3
—
Reserved
R/W
—
3
0x4E
28
0x50
2
—
Modbus ramp time
R/W
U16
4
0x4E
27
0x50
1
—
Reserved
R
—
5
0x4E
26
—
—
—
Status and fault word
R
—
6
0x4E
25
—
—
—
Field bus actual speed
R
S16
7
0x4E
24
—
—
P00-05
Motor current
R
U16
8
0x4E
23
—
—
—
Reserved
R
—
9
0x4E
22
—
—
—
Reserved
R
—
10
0x4E
21
—
—
P00-04
DI status
R
Binary code
11
0x4E
20
—
—
P00-20
Type
R
WORD
12
0x4E
19
—
—
P00-20
Power
R
U16
13
0x4E
18
—
—
P00-20
Voltage level
R
U16
14
0x4E
17
—
—
P00-18
Control section software version
R
WORD
15
0x4E
16
—
—
P00-18
Power section software version
R
WORD
16
0x4E
15
—
—
P00-20
Variable frequency drive recognition
R
WORD
17
0x4E
14
—
—
—
Reserved
R
—
18
0x4E
13
—
—
—
Reserved
R
—
19
0x4E
12
—
—
P00-01
Value AI1
R
U16
20
0x4E
11
—
—
P00-02
Value AI2
R
U16
21
0x4E
10
—
—
P00-03
Reference input speed
R
S16
22
0x4E
9
—
—
P00-08
DC link voltage
R
U16
23
0x4E
8
—
—
P00-09
Temperature in power section
R
S16
24
0x4E
7
—
—
P00-10
DE1 operating time
R
—
25
0x4E
6
—
—
—
DE1 operating time
R
—
26
0x4E
5
—
—
P00-12
DE1 operating time since the last fault message
R
—
27
0x4E
4
—
—
—
DE1 operating time since the last fault
R
—
28
0x4E
3
—
—
—
Reserved
R
—
29
0x4E
2
—
—
—
Reserved
R
—
30
0x4E
1
—
—
1
Maximum Output Frequency
R/W
U16
129
0x4E
41
0x50
1
2
Minimum output frequency
R/W
U16
130
0x4E
40
0x50
1
3
Accel ramp time
R/W
U16
131
0x4E
39
0x50
1
4
Decel ramp time
R/W
U16
132
0x4E
38
0x50
1
5
Stop mode select
R/W
U16
133
0x4E
37
0x50
1
6
Energy save
R/W
U16
134
0x4E
36
0x50
1
7
Motor rated voltage
R/W
U16
135
0x4E
35
0x50
1
8
Motor rated current
R/W
U16
136
0x4E
34
0x50
1
9
Motor rated frequency
R/W
U16
137
0x4E
33
0x50
1
10
Motor rated speed
R/W
U16
138
0x4E
32
0x50
1
11
Boost voltage value
R/W
U16
139
0x4E
31
0x50
1
12
Process data access
R/W
U16
140
0x4E
30
0x50
1
13
Trip log
R/W
U16
141
0x4E
29
0x50
1
14
Access code
R/W
U16
142
0x4E
28
0x50
1
15
Function of the control terminals
R/W
U16
143
0x4E
27
0x50
1
16
Analog input AI1, signal range
R/W
U16
144
0x4E
26
0x50
1
17
Analog input AI1, gain (scaling)
R/W
U16
145
0x4E
25
0x50
1
18
Analog input AI1, inversion
R/W
U16
146
0x4E
24
0x50
1
19
Digital input DI3, Logic
R/W
U16
147
0x4E
23
0x50
1