26
User Manual
MN040024EN
Effective November 2016
DX-NET-ETHERNET2-2 fi eld bus connection
EtherNet/IP for variable frequency drive DE1/DC1
EATON
www.eaton.com
Table 15. Class 0x44 Modbus (Read/Write indicted number of parameters from Instance)
Drive
Mode
Type
Inst.
Read
service
Max
supported len
Write
service
Max
supported len
Para.
Description
—
Field bus command
R/W
WORD
1
0x4E
30
0x50
1
—
Field bus speed reference value 0.1 Hz
R/W
S16
2
0x4E
29
0x50
1
—
Reserved
R/W
—
3
0x4E
28
0x50
1
—
Modbus ramp time
R/W
U16
4
0x4E
27
0x50
1
—
—
R
—
5
0x4E
26
—
—
—
Status and fault word
R
—
6
0x4E
25
—
—
—
Field bus actual speed
R
S16
7
0x4E
24
—
—
—
Motor current
R
U16
8
0x4E
23
—
—
—
Reserved
R
—
9
0x4E
22
—
—
—
Reserved
R
—
10
0x4E
21
—
—
—
DI status
R
Binary code
11
0x4E
20
—
—
—
Type
R
WORD
12
0x4E
19
—
—
—
Power
R
U16
13
0x4E
18
—
—
—
Voltage level
R
U16
14
0x4E
17
—
—
—
Control section software version
R
WORD
15
0x4E
16
—
—
—
Power section software version
R
WORD
16
0x4E
15
—
—
—
variable frequency drive recognition
R
WORD
17
0x4E
14
—
—
—
Reserved
R
—
18
0x4E
13
—
—
—
Reserved
R
—
19
0x4E
12
—
—
—
Value AI1
R
U16
20
0x4E
11
—
—
—
Value AI2
R
U16
21
0x4E
10
—
—
—
Reference input speed
R
S16
22
0x4E
9
—
—
—
DC link voltage
R
U16
23
0x4E
8
—
—
—
Variable frequency drive temperature
R
S16
24
0x4E
7
—
—
—
Variable frequency drive operating time
R
—
25
0x4E
6
—
—
—
Variable frequency drive operating time
R
—
26
0x4E
5
—
—
—
The variable frequency drive operating time
since the last fault
R
—
27
0x4E
4
—
—
—
The variable frequency drive operating time
since the last fault
R
—
28
0x4E
3
—
—
—
—
R
—
29
0x4E
2
—
—
—
—
R
—
30
0x4E
1
—
—
P-01
Maximum frequency / maximum speed
R/W
U16
129
0x4E
53
0x50
1
P-02
Minimum frequency / minimum speed
R/W
U16
130
0x4E
52
0x50
1
P-03
Acceleration time (acc1)
R/W
U16
131
0x4E
51
0x50
1
P-04
Deceleration time (dec1)
R/W
U16
132
0x4E
50
0x50
1
P-05
Stop Function
R/W
U16
133
0x4E
49
0x50
1
P-06
Energy optimization
R/W
U16
134
0x4E
48
0x50
1
P-07
Nominal motor voltage
R/W
U16
135
0x4E
47
0x50
1
P-08
Rated motor current
R/W
U16
136
0x4E
46
0x50
1
P-09
Rated motor frequency
R/W
U16
137
0x4E
45
0x50
1
P-10
Nominal speed of the motor
R/W
U16
138
0x4E
44
0x50
1
P-11
Voltage amplification
R/W
U16
139
0x4E
43
0x50
1
P-12
Control level
R/W
U16
140
0x4E
42
0x50
1
P-13
Fault log history
R/W
U16
141
0x4E
41
0x50
1
P-14
Access code (P-15 to P-53
A
101)
R/W
U16
142
0x4E
40
0x50
1
P-15
Function of digital inputs
R/W
U16
143
0x4E
39
0x50
1
P-16
Analog input 1 (AI1), signal range
R/W
U16
144
0x4E
38
0x50
1
P-17
Pulse frequency
R/W
U16
145
0x4E
37
0x50
1
P-18
K1 signal (Relay Output 1)
R/W
U16
146
0x4E
36
0x50
1
P-19
K1-Limit value (relay)
R/W
U16
147
0x4E
35
0x50
1