DSP 600
11
If the amplifier type connected to the DSP 600 is not included in the list, select the entry User. In this case you have to
adjust the parameter Gain manually. Check the technical specification of your amplifier for the gain value.
If the correct gain value is unknown set the parameter Amp to Default. For this setting a gain of 39dB is used, this is
sufficient for most amplifiers. By selecting the right amplifier type the limiter settings of the channel are adapted auto-
matically, so the connected speakers are protected as required. Ensure the level of the amplifier is set to 0dB to get the
maximum power from the amps.
C
ONFIGURE
D
ELAY
The DSP 600 can be used to compensate for the positioning of cabinets or speaker arrays relative to each other or the
original sound source. Press the SPEAKER Delay button for adjusting one or more output channels and select Active in
this dialog. Select the prefered Unit (using cm as unit is recommended) and edit the setting of the parameter Delay.
Setting the correct Delay value is important to avoid acoustic cancellation of signals. E.g. when using the two fullrange
channels of the configuration "2way + FR" as delay lines, the Delay of this two channels has to be adjusted according to
the distance to the main PA. If all connected speakers are used as a delay line, or the main PA should be moved acous-
tically „back to the stage”, the input delay parameter of input channels A and/or B should be used in this cases. Press
the USER Delay button to use the input delay, up to 2 seconds of delay are available for each input.
C
ONFIGURE
E
QUALIZER
Use the GEQ (31 band) and PEQ (10 band) of each input channel for adjusting the sound of your system to your room
characteristics. Press the USER PEQ or GEQ button to open the equalizer dialogs.
OUT 1:Level/Limiter
Level: 6.0dB
Polarity:Inv
Amp: User
Gain: 39dB
OUT 1:Output Delay
Active
Delay: 7.0
Unit: ms
IN A:PEQ1
Active
Type: Hipass
F: 20000.0Hz
Slope: 12dB/oct
Q: 2.0
IN A:GEQ Detail
F:20Hz Gain:0.0dB Active
Type: Symmetric Q
Q: 4.3
Summary of Contents for DSP 600
Page 1: ...DSP 600 FIR TUNE SOUND SYSTEM PROCESSOR Owner s Manual Bedienungsanleitung Mode d emploi...
Page 5: ...DSP 600 5...
Page 46: ...DYNACORD 46...
Page 48: ...DYNACORD 48 1 bersicht...
Page 89: ...DSP 600 89...
Page 92: ...DYNACORD 92...
Page 136: ...DYNACORD 136 8 3 Signal flow chart...
Page 138: ...DYNACORD 138 9 3 12 dB PEQ Cuts Q Changes 9 4 12dB Oct Shelves at 200 Hz and 2 kHz...
Page 139: ...DSP 600 139 9 5 Bessel Filters 9 6 Butterworth Filters...
Page 140: ...DYNACORD 140 9 7 Hi Lo Pass Filters 9 8 Linkwitz Riley Filters...
Page 142: ...DYNACORD 142...
Page 143: ...DSP 600 143...