DYNACORD
10
2.4 Quick Start
C
ONNECT
DSP 600
Connect the signal inputs and outputs of the DSP 600 (console - DSP 600 - amplifier). You must make sure that each
output is connected to the correct amplifier and loudspeaker(s). The DSP 600 must be connected to A.C. power only
by means of the provided IEC A.C. cable or by a power cable provided by the dealer / installer to match the configuration
of your country or region. After power-up the number and name of the last loaded preset and the configuration mode is
indicated.
R
ECALL
P
RESET
Press the Recall button and select the factory preset matching to your speaker configuration. Press the Recall button
again to activate the preset. If the configuration of the DSP 600 changes the Recall button has to be pressed a third time.
The configuration LEDs indicate the function of each output channel. Full range is indicated by all lit LEDs.
CAUTION:
The parameter settings of the DSP 600 factory presets are highly optimized and should not be changed.
Especially editing X-Over, PEQ or Limiter settings can result in damaged speakers.
The following steps are shown for one output channel only.
C
ONFIGURE
L
EVEL
Press the Level button to open the Level/Limiter dialog.
The Level parameter allows adjustment of the level ratio between sub and top speakers. E.g. if the parameters in a pre-
set are optimized for 2 subs you can increase the sub level by 6 dB if you are using 1 sub in your application. As an
alternative you can decrease the top level by 6 dB.
S
ELECT
AMPLIFIER
TYPE
Select the power amp type connected to the DSP 600 using the parameter Amp. Please note there are multiple entries
for an amplifier type if the amplifier allows different sensitivity settings.
Illustration 2-1: Output assignment LEDs
Default User Preset 1
FREE CONFIGURATION
U01
DYNACORD DSP 600
OUT 1:Level/Limiter
Level: 6.0dB
Polarity:Inv
Amp: User
Gain: 39dB
OUT 1:Level/Limiter
Level: 6.0dB
Polarity:Inv
Amp: H 5000 (0 dBu)
Summary of Contents for DSP 600
Page 1: ...DSP 600 FIR TUNE SOUND SYSTEM PROCESSOR Owner s Manual Bedienungsanleitung Mode d emploi...
Page 5: ...DSP 600 5...
Page 46: ...DYNACORD 46...
Page 48: ...DYNACORD 48 1 bersicht...
Page 89: ...DSP 600 89...
Page 92: ...DYNACORD 92...
Page 136: ...DYNACORD 136 8 3 Signal flow chart...
Page 138: ...DYNACORD 138 9 3 12 dB PEQ Cuts Q Changes 9 4 12dB Oct Shelves at 200 Hz and 2 kHz...
Page 139: ...DSP 600 139 9 5 Bessel Filters 9 6 Butterworth Filters...
Page 140: ...DYNACORD 140 9 7 Hi Lo Pass Filters 9 8 Linkwitz Riley Filters...
Page 142: ...DYNACORD 142...
Page 143: ...DSP 600 143...