) parameter
Configure and allocate the outputs here. The table shows the outputs and
their allocation. The pins on the circuit board are labeled and must be
allocated according to the table, depending on what was connected to
the pin.
A mode can be allocated to every output (parameter T 56 00). The follow-
ing table lists the modes:
Machine output signal
Output
ML (X22)
X120B.9
NK (X22)
X120B.10
RA (X16)
X120B.12
STL (X17)
X120B.22
STL(FA) (X18)
X120B.23
FL (X15) (X22)
X90.12
FF3 OUT (X22)
X90.15
Mode
Function
0
No function assigned
1
Needle cooling
2
Cleaning signal for the remaining thread monitor
3
Pos 1 (needle down)
4
Pos 2 (top dead center)
5
Motor running signal
6
Puller/seam center guide
7
Sewing foot lift signal
8
Puller
9
Puller pressure
10
Bartack
11
Bartack process
12
Thread cutter
13
In the seam
14
Segment Output 1
15
Segment Output 2
16
Segment Output 3
17
Segment Output 4
18
Segment Output 5
Summary of Contents for 667 PREMIUM
Page 1: ...667 PREMIUM Service Instructions...
Page 10: ...About these instructions 8 Service Instructions 667 PREMIUM 03 0 01 2018...
Page 28: ...Working basis 26 Service Instructions 667 PREMIUM 03 0 01 2018...
Page 70: ...Thread cutter 68 Service Instructions 667 PREMIUM 03 0 01 2018...
Page 120: ...Programming 118 Service Instructions 667 PREMIUM 03 0 01 2018...
Page 130: ...Maintenance 128 Service Instructions 667 PREMIUM 03 0 01 2018...
Page 132: ...Decommissioning 130 Service Instructions 667 PREMIUM 03 0 01 2018...
Page 134: ...Disposal 132 Service Instructions 667 PREMIUM 03 0 01 2018...
Page 146: ...Troubleshooting 144 Service Instructions 667 PREMIUM 03 0 01 2018...
Page 149: ......