Operating manual part II
II-22
© 2013 Dürkopp Adler AG
Level
Code
Error description
Corrective
- Check the thread lever up position (Position 2)
Error
3100
AC RDY timeout , intermediate circuit
voltage has not reached the defined
threshold in the given time.
- Check mains voltage
- If mains voltage OK, replace control unit
Error
3101
High voltage error, mains voltage
>290V for some time
- Check mains voltage, if rated voltage exceeded
permanently - stabilise or use generator
Error
3102
Low voltage failure (2nd threshold)
(mains voltage < 150V AC)
- Check mains voltage
- Stabilise mains voltage
- Use generator
Information 3103
Low voltage warning (1st threshold)
(mains voltage < 180V AC)
- Check mains voltage
- Stabilise mains voltage
- Use generator
Warning
3104
Pedal position is not at position 0
When switching on the control unit, take foot off pedal
Error
3105
Short circuit U24V
- 37 pin Take plug out, if error 3105 continues, replace
control unit
- Test inputs/ outputs for 24V short circuit
Error
3106
Overload U24V (I²T)
- one or more of the magnets faulty
Error
3107
Pedal not connected
- connect analogue pedal
Information 3108
Speed limiting because the power
supply is to low
- check your power supply
Warning
3109
Maintaining safety
- Check the tipping sensor on the machine
Information 3150
Maintenance required (info)
- For information on lubricating the machine see the
machine's service instructions
Warning
3151
Maintenance required (continue only
when parameters reset
t 51 14, see machine's operating
instructions)
- carry out service urgently, see machine's service
instructions
Information 3215
Bobbin thread ounter (info value 0
reached)
- Change reel, set counter value - press counter reset
button
Information 3216
Bobbin thread monitor left
- Change left bobbin
Information 3217
Bobbin thread monitor right
- Change right bobbin
Information 3218
Bobbin thread monitor left and right
- Change left and right bobbin
Error
6353
Internal EEprom communication error
- Switch off control unit, wait until the LEDs go out and
turn on again.
Error
6354
External EEprom communication error
- Switch off control unit, wait until the LEDs go out and
check the connection of the mach-ID. Turn the control
on.
Information 6360
No valid data on external EEprom
- Update software. The internal data structures are not
compatible with the external data memory
Information 6361
No external Eeprom connected
- Plug in mach ID
Information 6362
No valid data on internal EEprom
- Check connection mach-ID
- Switch off control unit, wait until the LEDs go out and
turn on again.
- Update software. The internal data structures are not
compatible with the external data memory
Information 6363
No valid data on internal or external
EEprom
(only emergency run features)
- Check connection mach-ID
- Switch off control unit, wait until the LEDs go out and
turn on again.
- Update software. The software version is not
compatible with the internal data memory
Information 6364
No valid data on internal EEprom and
external EEprom not connected
(only emergency run features)
- Check connection mach-ID
- Switch off control unit, wait until the LEDs go out and
turn on again.
- Update software. The internal data structures are not
compatible with the external data memory
Information 6365
Internal EEprom faulty
- Replace control unit
Information 6366
Internal EEprom faulty and external
- Replace control unit