Operating manual part II
II-14
© 2013 Dürkopp Adler AG
L
C
P
Min
Max
Preset Unity
Description
Machine run blockage
t
50 00 0
1
1
-
Machine run blockage
0 = off;
1 = on
t
50 01 0
1
0
-
The mode of operation from machine run blockage switch
0 = NC;
1 = NO
t
50 02 0
1
1
-
Emergency shutdown of the motor or motor places
0 = Emergency shutdown;
1 = Direct positioning
Miscellaneous of the control
t
51 00 -
-
-
-
Showing software version
t
51 01 -
-
-
-
Showing control serial number
t
51 02 0
1
0
-
Show the analog value (t 51 12) during sewing process.
0 = No;
1 = Yes
t
51 04 -
-
-
-
Showing machine class and –sub class
t
51 05 -
-
-
-
Showing hours of operation
t
51 06 -
-
-
-
Showing stitches of operation
t
51 07 -
-
-
-
Showing piece counter
t
51 10 0
4
-
-
Load of parameters
0 = Nothing;
1 = Sewing data from the dongle;
2 = Sewing data of the backup area;
3 = Seam ways from the Dongle
4 = Master reset
t
51 11 0
3
-
-
Store of parameters
0 = Nothing;
1 = Sewing data to the dongle;
2 = Sewing data to the backup area;
3 = Seam ways to the Dongle