Automatic corner knife station (straight pocket)
Service Instructions 755 A/756 A - 00.0 - 02/2019
141
Setting the reference switch
Testing the initial position of the corner knives manually (3)
To set the reference switch:
8. Swivel out the corner knife station.
The distance between the reference switch (6) and the screw (7)
must be 0.5 mm.
9. Loosen the nut (5) at the reference switch (6).
10. Swivel down the reference switch (6) until the switching head lines up
precisely with the nut (5).
11. Tighten the nut (5).
12. Loosen the nut (8).
13. Loosen the screw (7) until the distance between screw (7) and
reference switch (6) is 0.5 mm.
14. Tighten the nut (8).
(5)
- Nut
(6)
- Reference switch
(7)
- Screw
(8)
- Nut
⑤
⑥
⑦ ⑧
Summary of Contents for 755 A
Page 1: ...755 A 756 A Service Instructions...
Page 8: ...Table of Contents 6 Service Instructions 755 A 756 A 00 0 02 2019...
Page 12: ...About these instructions 10 Service Instructions 755 A 756 A 00 0 02 2019...
Page 116: ...Folder 114 Service Instructions 755 A 756 A 00 0 02 2019...
Page 124: ...Transport carriage 122 Service Instructions 755 A 756 A 00 0 02 2019...
Page 138: ...Transport clamps 136 Service Instructions 755 A 756 A 00 0 02 2019...
Page 200: ...Light barriers 198 Service Instructions 755 A 756 A 00 0 02 2019...
Page 222: ...Endless zipper feed optional 220 Service Instructions 755 A 756 A 00 0 02 2019...
Page 238: ...Additional equipment 236 Service Instructions 755 A 756 A 00 0 02 2019...
Page 266: ...Stacker 264 Service Instructions 755 A 756 A 00 0 02 2019...
Page 438: ...Programming 436 Service Instructions 755 A 756 A 00 0 02 2019...
Page 450: ...Decommissioning 448 Service Instructions 755 A 756 A 00 0 02 2019...
Page 452: ...Disposal 450 Service Instructions 755 A 756 A 00 0 02 2019...
Page 472: ...Technical data 470 Service Instructions 755 A 756 A 00 0 02 2019...
Page 496: ...Appendix 494 Service Instructions 755 A 756 A 00 0 02 2019...
Page 497: ......