Multi-functional corner knife station
Service Instructions 755 A/756 A - 00.0 - 02/2019
175
5. Press the
Base corner
button.
6. Set the value to
0
and press
OK
to confirm.
Fig. 172: Adjusting the corner knives electrically (3)
7. Use the buttons
and
to align the corner knife supports.
The corner knife supports must be flush to one another.
8. Use the buttons
,
,
and
to align the corner knife
supports such that they are straight.
Offset corner knife at seam end left zero
• only for configuration: multi-functional corner knife station
• 0° - 30°
Set corner knife correction seam end
• -99.9 mm - 99.9 mm
Offset corner knife at seam end right zero
• only for configuration: multi-functional corner knife station
• 0° - 30°
Symbols
Meaning
flush
flush
Summary of Contents for 755 A
Page 1: ...755 A 756 A Service Instructions...
Page 8: ...Table of Contents 6 Service Instructions 755 A 756 A 00 0 02 2019...
Page 12: ...About these instructions 10 Service Instructions 755 A 756 A 00 0 02 2019...
Page 116: ...Folder 114 Service Instructions 755 A 756 A 00 0 02 2019...
Page 124: ...Transport carriage 122 Service Instructions 755 A 756 A 00 0 02 2019...
Page 138: ...Transport clamps 136 Service Instructions 755 A 756 A 00 0 02 2019...
Page 200: ...Light barriers 198 Service Instructions 755 A 756 A 00 0 02 2019...
Page 222: ...Endless zipper feed optional 220 Service Instructions 755 A 756 A 00 0 02 2019...
Page 238: ...Additional equipment 236 Service Instructions 755 A 756 A 00 0 02 2019...
Page 266: ...Stacker 264 Service Instructions 755 A 756 A 00 0 02 2019...
Page 438: ...Programming 436 Service Instructions 755 A 756 A 00 0 02 2019...
Page 450: ...Decommissioning 448 Service Instructions 755 A 756 A 00 0 02 2019...
Page 452: ...Disposal 450 Service Instructions 755 A 756 A 00 0 02 2019...
Page 472: ...Technical data 470 Service Instructions 755 A 756 A 00 0 02 2019...
Page 496: ...Appendix 494 Service Instructions 755 A 756 A 00 0 02 2019...
Page 497: ......