SPA Actuator with Intelli-Motion™ Technology Manual R00
May 2022
Page 29 of 48
bit2
Retracting n/a: bool
0
1
Actuator executing a retract
movement
bit3
Faulted n/a: bool
0
1
Actuator is faulted
bit4
At_Extend_Limit n/a: bool
0
1
Actuator has reached its extend
limit
bit5
At_Retract_Limit n/a: bool
0
1
Actuator has reached its retract
limit
bit6
In_Position
(GOTO mode)
n/a: bool
0
1
Actuator has reached its
TargetPosition (GOTO mode)
bit7
Position_Outside_
of_limits
n/a: bool
0
1
Actuator is positioned outside of
limits
bit8
CMD_Not_
Executed
n/a: bool
0
1
Command was not executed
bit9
Limit_Pair_
Selection_Invalid
n/a: bool
0
1
Invalid limit pair selector received
bit10
Active_Limit_
Value_Invalid
n/a: bool
0
1
Invalid active/selected limit
received
bit11
Stored_Limit_
Value_Invalid
n/a: bool
0
1
Invalid stored limit received
bit12
Speed_Invalid n/a: bool
0
1
Invalid speed value received
bit13
TargetPosition_
Invalid
n/a: bool
0
1
Invalid target position received
bit14
ControlMode_
Invalid
n/a: bool
0
1
Invalid control mode received
bit15
Speed_Limits_
Invalid
n/a: bool
0
1
Invalid speed limits received
INT
Unused (Pad)
46
INT:bits
FaultMovementBits
48
bit0
Stall n/a:bool
0
1
Actuator motor has stalled
bit1 Reverse_Movement n/a:bool
0
1
Reverse movement has occurred
bit2
VAC_Power_Loss n/a:bool
0
1
VAC Power Loss
bit3
Incompatible_
Commands
n/a:bool
0
1
Incompatible commands have
been received
bit4
Motor_Control_
Faulted
n/a:bool
0
1
Motor control has a fault
bit5
Motor_Control_
Mismatch
n/a:bool
0
1
Motor control indicated a
mismatch between commanded
and operating states
SMART Actuator Implicit / I/O Messaging Data Structures
Actual Order/Type
Target to Originator (FEEDBACK MESSAGE)
60 Bytes/SINT Total
Byte Order: LSB
Data Type
Name
Eng Unit
Min
Max
Description
StartIndex(byte)