27
3.4. Probe
As the standard probes, four types of the probe (AZ410, AZ411, AZ412 and AZ413) are
available for an additional order. Please contact us or your local distributor for ordering the
probe.
For the connection specification of each probe, see the NETIMPRESS next Instruction Manual,
Section 8. 5. “Target Interface”.
AZ411/AZ413
Most of I/O lines of NETIMPRESS have 1MΩ pull-down resistors between the GND line and
signal lines. Also, control lines from NETIMPRESS that are used on the target system must be
kept negated not to disturb the target system when connectors for NETIMPRESS are removed.
It is recommended to either pull up the power or pull down the GND signal for these control
lines with about 10KΩ resistors on the user system.
In case the pull-up resistor of about 10KΩ cannot be added to the control signals within the
user system, use AZ411/AZ413.
AZ411/AZ413 enables you to optionally add pull-up/pull-down resistors to the control lines
running from NETIMPRESS.
NET IMPRESS
Target system
AZ411/AZ413
IC clip
or
Untreated cable end