14
(1) Device Function [FUNC 0]
Set up a target area to execute the Device Functions such as reading, programming, etc.
Normally, set up the same areas as those you set up for the Flash ROM described in the
Section 2.2.1 (2).
The Device Function [FUNC 0] is automatically aligned with the block boundary address of a
flash memory by its specified address as shown in Figure 2-2-2-1.
The device functions will be executed to this automatically aligned area.
(2) Buffer Area [FUNC F5]
Set up an area to save the data or to load the file to be programmed on the buffer memory of
NET IMPRESS.
Normally, set up the same areas as those you set up for the Flash ROM described in the
Section 2.2.1 (2).
Figure 2-2-2-2 shows how the Device Function [FUNC 0], Buffer Area [FUNC F 5] and Flash
ROM Area [FUNC D 6] relate with each other.
(3) Verify Mode
Set up the Verify Mode when executing E. P. R and PROGRAM.
For the settings and operation of the Verify Mode, see the Section 2.3. Device Functions and
Their Operation.
(4) OK
Click this “OK” button to send the settings on the Basic Operation tab into the Control Module.
When you made changes to the above (1) to (3) settings, be sure to click the OK button before
moving to other tabs.