33
[29]
Low Battery Reporting Codes, Zones 1 to 10
Program ten 2-digit Low Battery Reporting Codes in this section; refer to Programming Section
[23] for programming instructions.
These codes will be transmitted to report low battery conditions for the devices assigned to
zones 1 through 10.
[30]
Low Battery Restoral Reporting Codes, Zones 1 to 10
Program ten 2-digit Low Battery Restoral Reporting Codes in this section; refer to Programming
Section [23] for programming instructions.
These codes will be transmitted to report low battery restorals for the devices assigned to zones
1 through 10.
[31]
Supervisory Reporting Codes, Zones 1 to 10
Program ten 2-digit Supervisory Reporting Codes in this section; refer to Programming Section
[23] for programming instructions. These codes will be transmitted to report supervisory events
for zones 1 through 10.
A Supervisory Event occurs when the Controller fails to receive a signal from a system
component. If any component fails to “report in” with the Controller, a “Sensor Fault” condition
will be indicated on the Keypad and Sounder, and a Supervisory Reporting Code for the
affected zone will be transmitted to the monitoring station.
[32]
Supervisory Restoral Reporting Codes, Zones 1 to 10
Program ten 2-digit Supervisory Restoral Reporting Codes in this section; refer to Programming
Section [23] for programming instructions. These codes will be transmitted to report supervisory
event restorals for zones 1 through 10.
Supervisory restoral codes will be transmitted when the “Sensor Fault” reported for a zone is
restored.
[33]
Priority Alarms and Restorals: [F], [A], [P] and Fire Zone Trouble
Program eight 2-digit reporting codes in this section; refer to Programming Section [23] for
programming instructions.
These reporting codes are used to report Keypad Zone Alarms and Restorals. The following
codes are programmed in this section:
1
Keypad [F] Key Alarm
2
Keypad [A] Key Alarm
3
Keypad [P] Key Alarm
4
Fire Zone Trouble
5
Keypad [F] Key Restoral
6
Keypad [A] Key Restoral
7
Keypad [P] Key Restoral
8
Fire Zone Trouble Restore
Notes on Fire Zone Troubles
A Fire Zone Trouble will be generated when a smoke detector has a low battery or low
sensitivity condition.
If a Fire Zone Trouble is indicated, replace the batteries in the affected smoke detector. For
information on the batteries required, refer to Chapter 1 B: Components.
If replacing the batteries does not correct the Fire Zone Trouble, the detector may have a low
sensitivity condition. Dirt in the smoke detector or environmental conditions may cause the
detector’s automatic self-test to report a low sensitivity condition. The trouble condition will be
restored when the sensitivity returns to normal. If the low sensitivity condition is due to
environmental conditions, the smoke detector may return to normal automatically.
Note: a Low Sensitivity Condition may require the detector be serviced at DSC.
If a Fire Zone Trouble condition is persistent, the smoke detector may need to be replaced.