23
XT SERIES INSTALLATION, OPERATION, AND MAINTENANCE MANUAL
Dispersion:
Models XTP 010 through 025
Hose clamp**
OM-7978_aa
Models XTP 002 through 006
1” (DN25) steam hose,
12" (305 mm) long
(optional)*
OM-7977
1½” (DN40) I.D.
steam hose**
1½” (DN40) steam hose
Connector
(optional)*
See Caution
below
To dispersion assembly
To dispersion assembly
INSTALLATION
Hose clamp
(optional)*
* Provided in optional connector kit Part No. 191070-100 (see Table 61-1)
** Provided by installer.
CAUTION
Connector kit location
Install the connector for increasing from 1” to 1½” (DN25 to DN40) hose or tube immediately above the XT Series humidifi er as
shown above.
Failure to install the connector kit immediately above the humidifi er will cause system pressure fl uctuations and increase cylinder
pressure, steam velocity, and condensate noise.
FIGURE 23-1: STEAM OUTLET CONNECTIONS, MODELS XTP 002 THROUGH 025
Steam outlet connections