background image

USER'S MANUAL

Dehumidifier

ES10014US

UNITED STATES

CANADA

UNITED KINGDOM

GERMANY

FRANCE

ITALY

SPAIN

JAPAN

RUSSIA

AUSTRALIA

With your inspiring rating, COSTWAY will be more consistent to offer you EASY 

SHOPPING EXPERIENCE, GOOD PRODUCTS and EFFICIENT SERVICE!

Mit Ihrer inspirierenden Bewertung wird COSTWAY konsistenter sein, um Ihnen 

EIN SCHÖNES EINKAUFSERLEBNIS, GUTE PRODUKTE und EFFIZIENTEN 

SERVICE zu bieten!

Avec votre évaluation inspirante, COSTWAY continuera à fournir une 

EXPÉRIENCE D’ACHAT PRATIQUE, des PRODUITS DE QUALITÉ et un 

SERVICE EFFICACE !

Con su calificación inspiradora, COSTWAY será más consistente para ofrecerle 

EXPERIENCIA DE COMPRA FÁCIL, BUENOS PRODUCTOS y SERVICIO 

EFICIENTE.

Con la tua valutazione incoraggiante, COSTWAY sarà più coerente per offrirti 

ESPERIENZA DI ACQUISTO FACILE, BUONI PRODOTTI e SERVIZIO 

EFFICIENTE!

Dzięki  twojej  opinii  COSTWAY  będzie  mógł  oferować  jeszcze WYGODNIEJSZE 

ZAKUPY, LEPSZE PRODUKTY i SPRAWNIEJSZĄ OBSŁUGĘ KLIENTA.

US office: Fontana

UK office: Ipswich

DE office: FDS GmbH, Neuer Höltigbaum 36, 22143 Hamburg, Deutschland

FR office : 26 RUE DU VERTUQUET, 59960 NEUVILLE EN FERRAIN, FRANCE

Summary of Contents for ES10014US

Page 1: ...à fournir une EXPÉRIENCE D ACHAT PRATIQUE des PRODUITS DE QUALITÉ et un SERVICE EFFICACE Con su calificación inspiradora COSTWAY será más consistente para ofrecerle EXPERIENCIA DE COMPRA FÁCIL BUENOS PRODUCTOS y SERVICIO EFICIENTE Con la tua valutazione incoraggiante COSTWAY sarà più coerente per offrirti ESPERIENZA DI ACQUISTO FACILE BUONI PRODOTTI e SERVIZIO EFFICIENTE Dzięki twojej opinii COSTW...

Page 2: ...ts on the appliance 8 Do not tip the unit to any side as spilled water may damage the appliance 9 Never insert any other object into the unit body to avoid any hazard or unit failure 10 Do not put the unit close to heat generating devices or near flammable and dangerous materials 11 This appliance is not intended for use by persons including children with reduced physical sensory or lack of experi...

Page 3: ...IONS Model No Power Supply Power Consumption Rated Current Dehumidify Capacity Noise Full Water Quantity Refrigerant Charge Recommend Room Size Body Size Net Weight OL12 D023A AC115V 60Hz 195W 86 80 RH 2 0A 86 80 RH 24Pints Day 86 80 RH 36dB A 2 0L R134a 105g 161 269 sq ft 10 x805 x18 23 lbs Touch panel Front shell Air outlet Castors Back shell Air filter Continuous drainage water tank visiable wa...

Page 4: ...n environmental humidity 63 the fan starts working and compressor starts working after 3 seconds Fan speed and humidity can not be adjusted under sleeping mode Timer Press the timer button to set the 0 12 hour timing function The interval is 1 hour Each time you press this button the value increased 1 hour and then the corresponding timing value is displayed on the screen The setting value is 00 t...

Page 5: ... and pull it out with both hands Take it slowly and steadily in case of spilled water Empty the water Put the water tank back in position The dehumidifier automatically starts working again MAINTENANCE PRECAUTIONS Do not remove the float out of the tank otherwise the dehumidifier can not start up 1 If the tank is dirty wash it with cool warm water Do not use cleanser steel balls chemically treated...

Page 6: ...ked or damaged Spacing When the dehumidifier is in operation make sure that the rear of the dehumidifier maintains a minimum spacing of 11 8 inches as shown below CLEANING Body Cleaning Use a soft and slightly moist cloth to clean the dehumidifier body Filter Cleaning 1 Remove the filter frame and take off the filter 2 Use a vacuum cleaner to gently absorb the dust on the surface If the filter is ...

Page 7: ...sult of a defect in Problem Possible Cause Solution Not working No power supply Connect to a functioning outlet and switch on Bad functioning Is the air filter clogged Clean the air filter as instructed Loud noise when running Is the machine put in the flat place Put the machine on the plat ground Is the filter clogged Wash the filter No air intake Is the filter clogged Wash the filter E2 Humidity...

Reviews: