3. Put the filter back.
STORAGE
When not using the product for a long time and intend to store it, please pay
attention to the following steps:
1.Empty the water in the water tank and wipe the water droplets on bottom of
inside machine.
2.Collect the power cord and store it in the dry water tank.
3.Clean the filter.
4.Place the machine in a cool and dry environment.
TROUBLE SHOOTING
1. FUNCTIONING TEMP.
41°F ≤ Ambient Temp. ≤ 95°F
When the ambient temp is lower or higher than the functioning temp, the
dehumidifier stops.
When 41°F ≤ Ambient temp. ≤ 60.8°F, the compressor automatically defrosts
at intervals; during defrosting, the compressor stops and the fan keeps
running.
2.BEFORE CALLING FOR SERVICE
Before contacting professional service, please review the trouble shooting list
that includes common occurrences that are not the result of a defect in
Problem
Possible Cause
Solution
Not working
No power supply
Connect to a functioning
outlet and switch on
Bad functioning
Is the air filter clogged?
Clean the air filter as
instructed
Loud noise
when running
Is the machine put in the
flat place?
Put the machine on the
plat ground
Is the filter clogged?
Wash the filter
No air intake
Is the filter clogged?
Wash the filter
E2
Humidity sensor problem
LO
Environmental humidity is
below 20%
HI
Environmental humidity is
above 90%
CL
Low temperature protection,
the environmental
temperature
<
41
。F
CH
High temperature protection,
the environmental
temperature
>
95
。F
Change a sensor
The dehumidifier shuts
down for self- protection
Is the intake duct or
discharge duct obstructed?
Remove the obstruction
from the discharge duct
or intake duct.
Water Full Indication
Flashes
Drain water tank and reset
it, or re-position the water
tank to right place
Room temperature
˂ 41°F,or ˃ 95 °F
Self-Protection designed to
protect the unit. Can not work
under such temperature
12